My Zelden IPLINFO shows OPI=YES and set by IEASYSD0. Do a D PARMLIB and ensure you are pulling the correct IEASYS00 member and have coded OPI=NO.
My D IPLINFO shows the same as yours with respect to (OP) being shown and we don’t prompt either (M1 coded in Load parm). On Wed, Apr 22, 2020 at 11:06 AM Carmen Vitullo <cvitu...@hughes.net> wrote: > I'm working an audit issue which has been identified as a system exposure. > I have in a shared parmlib IEASYS00 member OPI=NO, my IPLPARMS are set as > 220100M1, but the D IPLINFO shows > > SYSTEM IPLED AT 23.20.28 ON 04/01/2020 > RELEASE z/OS 02.03.00 LICENSE = z/OS > USED LOAD00 IN SYS1.IPLPARM ON 02201 > ARCHLVL = 2 MTLSHARE = N > IEASYM LIST = (00,L) > IEASYS LIST = (00,SA,20) (OP) > Marks IPLINFO rexx shows > > OPI=YES, Default > SYSP=(00,SA,20), Operator > we are setting OPI=NO > and are not prompting or setting SYSP parameters via an operator request. > I have an open PMR with IBM but I wonder if anyone else sees the same > displays ? > thanks > Carmen > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > -- Michael Babcock OneMain Financial z/OS Systems Programmer, Lead ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN