My Zelden IPLINFO shows OPI=YES and set by IEASYSD0.  Do a D PARMLIB and
ensure you are pulling the correct IEASYS00 member and have coded OPI=NO.

My D IPLINFO shows the same as yours with respect to (OP) being shown and
we don’t prompt either (M1 coded in Load parm).

On Wed, Apr 22, 2020 at 11:06 AM Carmen Vitullo <cvitu...@hughes.net> wrote:

> I'm working an audit issue which has been identified as a system exposure.
> I have in a shared parmlib IEASYS00 member OPI=NO, my IPLPARMS are set as
> 220100M1, but the D IPLINFO shows
>
>  SYSTEM IPLED AT 23.20.28 ON 04/01/2020
>  RELEASE z/OS 02.03.00    LICENSE = z/OS
>  USED LOAD00 IN SYS1.IPLPARM ON 02201
>  ARCHLVL = 2   MTLSHARE = N
>  IEASYM LIST = (00,L)
>  IEASYS LIST = (00,SA,20) (OP)
> Marks IPLINFO rexx shows
>
>  OPI=YES,                                                       Default
> SYSP=(00,SA,20),                                               Operator
> we are setting OPI=NO
> and are not prompting or setting SYSP parameters via an operator request.
> I have an open PMR with IBM but I wonder if anyone else sees the same
> displays ?
> thanks
> Carmen
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
-- 
Michael Babcock
OneMain Financial
z/OS Systems Programmer, Lead

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to