Well....looks like I've been busted! There are a couple of caveats.

Yes, CP supports it, but here are a few restrictions :
- CMS can only access a disk of 32,767 cylinders or less
- A (virtual) minidisk that is greater than 32,767 cylinders is not eligible for minidisk cache regardless of what is marked in the directory or conf file.
- A real disk track will not be brought into the minidisk cache if it exists above real cylinder 32,767 with recent APAR VM64115.

Regards, Steve.

Steve Wilkins
IBM z/VM Development
Inactive hide details for "Stracka, James (GTI)" <[EMAIL PROTECTED]>"Stracka, James (GTI)" <[EMAIL PROTECTED]>


          "Stracka, James (GTI)" <[EMAIL PROTECTED]>
          Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>

          11/10/2006 10:17 AM

          Please respond to
          The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>

To

IBMVM@LISTSERV.UARK.EDU

cc


Subject

Re: Mod 54 dasd on z/VM 5.2

Both CMS general users as well as CP?
      -----Original Message-----
      From:
      The IBM z/VM Operating System [mailto:IBMVM@LISTSERV.UARK.EDU] On Behalf Of Steve Wilkins
      Sent:
      Friday, November 10, 2006 10:01 AM
      To:
      IBMVM@LISTSERV.UARK.EDU
      Subject:
      Re: Mod 54 dasd on z/VM 5.2

      For the original question: Yes, VM 5.2.0 (as well as 5.1.0) supports a 3390 mod-54 DASD.

      Regards, Steve.

      Steve Wilkins
      IBM z/VM Development
      Ronald van der Laan <[EMAIL PROTECTED]>

                      Ronald van der Laan <[EMAIL PROTECTED]>
                      Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>

                      11/10/2006 09:51 AM

      Please respond to
      The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
      To

      IBMVM@LISTSERV.UARK.EDU
      cc
      Subject

      Re: Mod 54 dasd on z/VM 5.2

      Tom,

      The CP Planning and Adminstration guide: (2.9.4.3.3 Placing of the CSE Area, table 14)

      http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/HCSG0B11/2.9.4.3.3?SHELF=hcsh2a80&DT=20060516094207#TBLDEVMAP

      Shows for 3390-9 type dasd a maximun of 65520 cylinders.

      Ronald van der Laan