As a lark, I tried bring up VSE/ESA 2.7.2 up under a second level z/VM 5.2 (z/VM Version 5 Release 2.0, service level 0602 (64-bit) ) system that is running under z/VM 5.1 (z/VM Version 5 Release 1.0, service level 0501 (64-bit)).
No go. Right after "ipl restart point has been bypassed", I get: HCPGIR450W CP entered; disabled wait PSW 000A0000 00001000 DISPLAY 0:15 R00000000 1A000FD0 00000061 00000000 00000000 06 R00000010 000073B0 000005C8 I read it as a VSE cancel code, IO error. I buy that, but what device? It should be dasd at this point. On the first level system, I created VMTEST (the second level system). I copied over the mdisk statements from TSTESA5F to VMTEST. So now all minidisks needed by TSTESA5F, will appear to VMTEST as real disks. On the second level system, I changed the mdisk statements for TSTESA5F to DED statements. Well, it worked in the past. My immediate concern is, is there VSE maintenance that is needed to run on z/VM 5.2 over and above the maintenance that was needed to run on z/VM 5.1? (I thought the maintenance to run under z/VM 5.1 was more hardware related for the 64 bit z/890 then for running unde z/VM 5.1, but that was a while back.) Anyone hit this recently? I'm now concerned enough that, if I don't get a solution, I will be in this Christmas weekend to bring up z/VM 5.2 first level and bring up some of the test VSE systems up to validate I don't have any VSE related conversion problems. Thanks Tom Duerbusch THD Consulting