Hello Kevin,

 

            Thanks that is what I was looking for.

 

            I have this right now.

 

*


CU0130   CNTLUNIT CUNUMBR=0130,PATH=(30),CUADD=01,                     X


               UNITADD=((00,256)),UNIT=2105


CU0140   CNTLUNIT CUNUMBR=0140,PATH=(40),CUADD=01,                     X


               UNITADD=((00,256)),UNIT=2105


CU0131   CNTLUNIT CUNUMBR=0131,PATH=(31),CUADD=01,                     X


               UNITADD=((00,256)),UNIT=2105


CU0141   CNTLUNIT CUNUMBR=0141,PATH=(41),CUADD=01,                     X


               UNITADD=((00,256)),UNIT=2105


CU0230   CNTLUNIT CUNUMBR=0230,PATH=(30),CUADD=02,                     X


               UNITADD=((00,256)),UNIT=2105


CU0240   CNTLUNIT CUNUMBR=0240,PATH=(40),CUADD=02,                     X


               UNITADD=((00,256)),UNIT=2105


CU0231   CNTLUNIT CUNUMBR=0231,PATH=(31),CUADD=02,                     X


               UNITADD=((00,256)),UNIT=2105


CU0241   CNTLUNIT CUNUMBR=0241,PATH=(41),CUADD=02,                     X


               UNITADD=((00,256)),UNIT=2105


DV800    IODEVICE ADDRESS=(0800,256),CUNUMBR=(0130,0140,0141,0131),    X


               UNIT=3390


DV900    IODEVICE ADDRESS=(0900,256),CUNUMBR=(0241,0231,0230,0240),    X


               UNIT=3390


*


 

Ed Martin

330-588-4723

ext 40441

________________________________

From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Neubert, Kevin (DIS)
Sent: Thursday, December 06, 2007 4:39 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: REquest for IOCP for DS6800 FICON Z890

 

You definitely want and should take advantage of all four channels.
Your CHPIDs look okay to me, but consider something like the following
for your CNTLUNITs and IODEVICEs

CU130    CNTLUNIT CUNUMBR=130,PATH=(30),                               X

               UNITADD=((00,256)),CUADD=0,UNIT=2105                     

CU140    CNTLUNIT CUNUMBR=140,PATH=(40),                               X

               UNITADD=((00,256)),CUADD=0,UNIT=2105                     

CU131    CNTLUNIT CUNUMBR=131,PATH=(31),                               X

               UNITADD=((00,256)),CUADD=0,UNIT=2105                     

CU141    CNTLUNIT CUNUMBR=141,PATH=(41),                               X

               UNITADD=((00,256)),CUADD=0,UNIT=2105                     

CUA30    CNTLUNIT CUNUMBR=130,PATH=(30),                               X

               UNITADD=((00,256)),CUADD=1,UNIT=2105                     

CUA40    CNTLUNIT CUNUMBR=140,PATH=(40),                               X

               UNITADD=((00,256)),CUADD=1,UNIT=2105                     

CUA31    CNTLUNIT CUNUMBR=131,PATH=(31),                               X

               UNITADD=((00,256)),CUADD=1,UNIT=2105                     

CUA41    CNTLUNIT CUNUMBR=141,PATH=(41),                               X

               UNITADD=((00,256)),CUADD=1,UNIT=2105                     

DV800    IODEVICE ADDRESS=(0800,256),CUNUMBR=(130,140,131,141),        X

               UNIT=3390,UNITADD=00                                     

DV900    IODEVICE ADDRESS=(0900,256),CUNUMBR=(A30,A40,A31,A41),        X

               UNIT=3390,UNITADD=00                                     

Regards,

 

Kevin

 

________________________________

From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Edward M. Martin
Sent: Thursday, December 06, 2007 12:19 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: REquest for IOCP for DS6800 FICON Z890

 

Hello Everyone,

        I am just getting the IOCP ready for a ds6800 connected to four
ports on the Z890.

        I would like to some help with the IOCP.  

        Even though we have to have LPAR, there is only one  called
PROD.

        The FICON cards are the 2320 FICON Express SX.   Two 1 gig ports
per card.

I would like to have all four ports able to access all dasd.

        

I am figuring to have the DS6800 formated for  30 3390 mod 3, 306 3390
mod 9, and 30 3390 mod 27. (366 devices)

        I know that am missing some RESOURCE PARTITION and various CSS
commands.

        

        I am reading about them now.  And I still have lots of
questions.

        I would appreciate any insight and idea's.  Than

 

         CHPID PCHID=130,PATH=30,TYPE=FC,SHARED       .FICON DS6800  

         CHPID PCHID=131,PATH=31,TYPE=FC,SHARED       .FICON DS6800  

         CHPID PCHID=140,PATH=40,TYPE=FC,SHARED       .FICON DS6800  

         CHPID PCHID=141,PATH=41,TYPE=FC,SHARED       .FICON DS6800  

*********************************************************


*    chpids 130/131/140/141 paths 30/31/40/41           *


*    IBM ds6400 system                                  *


*********************************************************


*


CU130    CNTLUNIT CUNUMBR=130,PATH=(30,40),                            X


               UNITADD=((00,256)),UNIT=2105


CU140    CNTLUNIT CUNUMBR=140,PATH=(31,41),                            X


               UNITADD=((00,256)),UNIT=2105


DV800    IODEVICE ADDRESS=(0800,256),CUNUMBR=(130,140),                X


               UNIT=3390,UNITADD=00


DV900    IODEVICE ADDRESS=(0900,256),CUNUMBR=(140,130),                X


               UNIT=3390,UNITADD=00


*


Ed Martin

330-588-4723

ext 40441

Reply via email to