Kevin, Edward, Would not - CU0130 CNTLUNIT CUNUMBR=0130,PATH=(30,31,40,41),CUADD=01, X UNITADD=((00,256)),UNIT=2105 DV800 IODEVICE ADDRESS=(0800,256),CUNUMBR=(0130), X UNIT=3390 give you the same results?? HITACHI DATA SYSTEMS Raymond E. Noal Senior Technical Engineer Office: (408) 970 - 7978 ________________________________
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Edward M. Martin Sent: Thursday, December 06, 2007 2:05 PM To: IBMVM@LISTSERV.UARK.EDU Subject: Re: REquest for IOCP for DS6800 FICON Z890 Hello Kevin, Thanks that is what I was looking for. I have this right now. * CU0130 CNTLUNIT CUNUMBR=0130,PATH=(30),CUADD=01, X UNITADD=((00,256)),UNIT=2105 CU0140 CNTLUNIT CUNUMBR=0140,PATH=(40),CUADD=01, X UNITADD=((00,256)),UNIT=2105 CU0131 CNTLUNIT CUNUMBR=0131,PATH=(31),CUADD=01, X UNITADD=((00,256)),UNIT=2105 CU0141 CNTLUNIT CUNUMBR=0141,PATH=(41),CUADD=01, X UNITADD=((00,256)),UNIT=2105 CU0230 CNTLUNIT CUNUMBR=0230,PATH=(30),CUADD=02, X UNITADD=((00,256)),UNIT=2105 CU0240 CNTLUNIT CUNUMBR=0240,PATH=(40),CUADD=02, X UNITADD=((00,256)),UNIT=2105 CU0231 CNTLUNIT CUNUMBR=0231,PATH=(31),CUADD=02, X UNITADD=((00,256)),UNIT=2105 CU0241 CNTLUNIT CUNUMBR=0241,PATH=(41),CUADD=02, X UNITADD=((00,256)),UNIT=2105 DV800 IODEVICE ADDRESS=(0800,256),CUNUMBR=(0130,0140,0141,0131), X UNIT=3390 DV900 IODEVICE ADDRESS=(0900,256),CUNUMBR=(0241,0231,0230,0240), X UNIT=3390 * Ed Martin 330-588-4723 ext 40441 ________________________________ From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Neubert, Kevin (DIS) Sent: Thursday, December 06, 2007 4:39 PM To: IBMVM@LISTSERV.UARK.EDU Subject: Re: REquest for IOCP for DS6800 FICON Z890 You definitely want and should take advantage of all four channels. Your CHPIDs look okay to me, but consider something like the following for your CNTLUNITs and IODEVICEs CU130 CNTLUNIT CUNUMBR=130,PATH=(30), X UNITADD=((00,256)),CUADD=0,UNIT=2105 CU140 CNTLUNIT CUNUMBR=140,PATH=(40), X UNITADD=((00,256)),CUADD=0,UNIT=2105 CU131 CNTLUNIT CUNUMBR=131,PATH=(31), X UNITADD=((00,256)),CUADD=0,UNIT=2105 CU141 CNTLUNIT CUNUMBR=141,PATH=(41), X UNITADD=((00,256)),CUADD=0,UNIT=2105 CUA30 CNTLUNIT CUNUMBR=130,PATH=(30), X UNITADD=((00,256)),CUADD=1,UNIT=2105 CUA40 CNTLUNIT CUNUMBR=140,PATH=(40), X UNITADD=((00,256)),CUADD=1,UNIT=2105 CUA31 CNTLUNIT CUNUMBR=131,PATH=(31), X UNITADD=((00,256)),CUADD=1,UNIT=2105 CUA41 CNTLUNIT CUNUMBR=141,PATH=(41), X UNITADD=((00,256)),CUADD=1,UNIT=2105 DV800 IODEVICE ADDRESS=(0800,256),CUNUMBR=(130,140,131,141), X UNIT=3390,UNITADD=00 DV900 IODEVICE ADDRESS=(0900,256),CUNUMBR=(A30,A40,A31,A41), X UNIT=3390,UNITADD=00 Regards, Kevin ________________________________ From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Edward M. Martin Sent: Thursday, December 06, 2007 12:19 PM To: IBMVM@LISTSERV.UARK.EDU Subject: REquest for IOCP for DS6800 FICON Z890 Hello Everyone, I am just getting the IOCP ready for a ds6800 connected to four ports on the Z890. I would like to some help with the IOCP. Even though we have to have LPAR, there is only one called PROD. The FICON cards are the 2320 FICON Express SX. Two 1 gig ports per card. I would like to have all four ports able to access all dasd. I am figuring to have the DS6800 formated for 30 3390 mod 3, 306 3390 mod 9, and 30 3390 mod 27. (366 devices) I know that am missing some RESOURCE PARTITION and various CSS commands. I am reading about them now. And I still have lots of questions. I would appreciate any insight and idea's. Than CHPID PCHID=130,PATH=30,TYPE=FC,SHARED .FICON DS6800 CHPID PCHID=131,PATH=31,TYPE=FC,SHARED .FICON DS6800 CHPID PCHID=140,PATH=40,TYPE=FC,SHARED .FICON DS6800 CHPID PCHID=141,PATH=41,TYPE=FC,SHARED .FICON DS6800 ********************************************************* * chpids 130/131/140/141 paths 30/31/40/41 * * IBM ds6400 system * ********************************************************* * CU130 CNTLUNIT CUNUMBR=130,PATH=(30,40), X UNITADD=((00,256)),UNIT=2105 CU140 CNTLUNIT CUNUMBR=140,PATH=(31,41), X UNITADD=((00,256)),UNIT=2105 DV800 IODEVICE ADDRESS=(0800,256),CUNUMBR=(130,140), X UNIT=3390,UNITADD=00 DV900 IODEVICE ADDRESS=(0900,256),CUNUMBR=(140,130), X UNIT=3390,UNITADD=00 * Ed Martin 330-588-4723 ext 40441