On Friday, 12/07/2007 at 06:16 EST, Rick Troth <[EMAIL PROTECTED]> wrote:

> Handing each guest its own HBA (host bus adapter,
> the open systems term for and FCP adapter) kind of blows
> one of the reasons to go virtual.

Eh?  480 servers can use a single FCP adapter (chpid) concurrently. That's 
the whole point of N_port ID virtualization: 480 separate fabric 
endpoints.

Alan Altmark
z/VM Development
IBM Endicott

Reply via email to