>the operator didn't wait for the shutdown to finish before doing the IPL.
Then one would use SHUTDOWN REIPL

Note too that CP writes shutdown progress messages to its consoles; on
the HMC you can find them under Operating System Messages

2008/3/30, O'Brien, Dennis L <Dennis.L.O'[EMAIL PROTECTED]>:
> We've occasionally had to FORCE start a system after a planned shutdown,
>  and we can't find any reason why the shutdown wouldn't have completed
>  successfully.  We're thinking maybe the operator didn't wait for the
>  shutdown to finish before doing the IPL.  We recently changed from 3174
>  console controllers to OSA-ICC.  I've noticed that when the shutdown is
>  complete, we no longer see the completion message on the emulator
>  session.  Instead, we see a banner like this:
>
>   **    OSC Index 3  connected to OSC0180 via IP Addr
>  xxx.xxx.xxx.xxx:1024    **
>   **        LT Index=2  CSSID= 0 MIFID= 7 CU=0  UA=0   LUName=Lxxxx180
>  **
>   **       Type=2094-S54 Mfg=IBM SN=0000000xxxxx CHPID=66 Status=Active
>  **
>
>  I'm wondering if this banner appears BEFORE the shutdown has finished.
>  Does it?  If it does, I suppose I'll have to tell the operators to check
>  for a PSW wait state on the HMC before they IPL.
>
>                                                        Dennis
>
>  "A society that gets rid of all its troublemakers goes downhill."  --
>  Robert A. Heinlein
>
>
>


-- 
Kris Buelens,
IBM Belgium, VM customer support