Hello Everyone,

 

     I need some confirmation.  I am just amazed at the performance of
the DS6800 

 

     I just did the z/VM command FLASHCOPY on a 3390-mod 9 on DS6800 to
another 3390-mod 9 volume on the DS6800.

 

FLASHCOPY 8A2 0 END TO 8A1 0 END SYNCHRONOUS

 

     The command responded instantaneously.

 

SYNChronous


    tells CP to process the command immediately and does not allow you
to    

    enter any other commands until the hardware has accepted all
parameters, 

    all messages from the Enterprise Storage Server (ESS) subsystem have
been

    processed, and the FLASHCOPY command completes. 

 

Is the DS6800 and the FLASHCOPY really that fast or is there something
going on behind the 

scenes?

 

    

Performance has been pretty unbelievable but the FLASHCOPY was just too
fast.

 

Example Our Batch cycle at night use to take 5-5.5 hours.  Started at
midnight and 

Completeed around 5:30 am.

 

    Old system EMC SYMETRIC 8 gig of cache and 6 ESCON connections.

 

SWITCH to DS6800.

 

    

    DS6800 2 gig of cache with 4 FICON connections.

 

Batch cycle dropped by 1 hour without any other changes. Start at
midnight and completes

    around 4-4:30 am.       

                           

 

     

 

Ed Martin

330-588-4723

ext 40441

 

Reply via email to