Hello Everyone,
I need some confirmation. I am just amazed at the performance of the DS6800 I just did the z/VM command FLASHCOPY on a 3390-mod 9 on DS6800 to another 3390-mod 9 volume on the DS6800. FLASHCOPY 8A2 0 END TO 8A1 0 END SYNCHRONOUS The command responded instantaneously. SYNChronous tells CP to process the command immediately and does not allow you to enter any other commands until the hardware has accepted all parameters, all messages from the Enterprise Storage Server (ESS) subsystem have been processed, and the FLASHCOPY command completes. Is the DS6800 and the FLASHCOPY really that fast or is there something going on behind the scenes? Performance has been pretty unbelievable but the FLASHCOPY was just too fast. Example Our Batch cycle at night use to take 5-5.5 hours. Started at midnight and Completeed around 5:30 am. Old system EMC SYMETRIC 8 gig of cache and 6 ESCON connections. SWITCH to DS6800. DS6800 2 gig of cache with 4 FICON connections. Batch cycle dropped by 1 hour without any other changes. Start at midnight and completes around 4-4:30 am. Ed Martin 330-588-4723 ext 40441