On Wednesday, 12/17/2008 at 05:26 EST, Michael 
MacIsaac/Poughkeepsie/i...@ibmus wrote:
 
> -) Install a z/VM system onto DASD with the *highest* 5 addresses we 
have (we 
> install onto 3390-3s). Use the default labels of 540RES, 540SPL, ... 
> -) Immediately shut this system down and never IPL it again - this is 
the 
> "golden image" (OK, "never" is a strong word - later you may want to put 
an RSU 
> on it). 
> 
> -) Clone the 5 volumes to the target DASD (we use FLASHCOPY. Any disk 
copy tool 
> should work assuming you have access to both source and target disks)
> -) IPL the RES volume from the first target DASD in the correct LPAR - 
you 
> should not run into the problem I describe above since these DASD have 
lower 
> addresses

<cough>  Please update your SYSTEM CONFIG on the new RES volume to define 
those high addresses as Offline_at_IPL.

> Relabelling the system volumes is tricky.

Note that FLASHCOPY now includes a LABEL option.

Alan Altmark
z/VM Development
IBM Endicott

Reply via email to