I looked at the code real quick :-> it looks like you'll have to VARY OFF
then back ON the 2 real volumes that back B28A & B28B to refresh the field
being checked.  Sorry.

Do this with the VM/CP VARY command.

Steve Wilkins
IBM VM Development
z/VM I/O Strategy


|------------>
| From:      |
|------------>
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
  |Mark Pace <mpac...@gmail.com>                                                
                                                                     |
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
|------------>
| To:        |
|------------>
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
  |IBMVM@LISTSERV.UARK.EDU                                                      
                                                                     |
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
|------------>
| Date:      |
|------------>
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
  |01/14/2009 01:59 PM                                                          
                                                                     |
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
|------------>
| Subject:   |
|------------>
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|
  |Flashcopy                                                                    
                                                                     |
  
>--------------------------------------------------------------------------------------------------------------------------------------------------|





I just activated the license on our DS8100 for Point-in-time Copy.  But I'm
having a problem.
flashcopy b28a 0 b28b 0
HCPNFC332E Invalid control unit type - B28A
Ready(00332); T=0.01/0.01 13:52:00

So I thought maybe something needed to change some definition in the
DS8100.  I searched and searched and found nothing.  I searched IBMLink and
did not find anything for the HCPNFC332E error.  So on a whim I decided to
try it on my z/VSE guest that is running under this VM.
ixfp snap,syswk1:vsewk1

AR+0015 IXFP23D SNAP FROM CUU=286 CYL='0000' TO CUU=284 CYL='0000'
NCYL='0D0B'
 - REPLY 'YES' TO PROCEED

15 yes

AR 0028 1H09I   OPER INFO  SYSXXX=286

AR 0028         SUBSYSTEM STATUS CHANGE: FL-COPY RELATION ESTABLISHED

AR 0028 1H09I   OPER INFO  SYSXXX=284

AR 0028         SUBSYSTEM STATUS CHANGE: FL-COPY RELATION ESTABLISHED

AR 0015 IXFP22I SNAP TO  CUU= 284 STARTED AT 18:39:28 GMT  01/14/2009

AR 0015 IXFP20I SNAP FUNCTION COMPLETED   AT 18:39:28 GMT  01/14/2009

AR 0015 1I40I  READY

AR 0028 1H09I   OPER INFO  SYSXXX=284

AR 0028         SUBSYSTEM STATUS CHANGE: FL-COPY RELATION TERMINATED

AR 0028 1H09I   OPER INFO  SYSXXX=286

AR 0028         SUBSYSTEM STATUS CHANGE: FL-COPY RELATION TERMINATED


Worked perfectly.  So now I have to wonder why it does not work in z/VM.

--
Mark Pace
Mainline Information Systems
1700 Summit Lake Drive
Tallahassee, FL. 32317

Reply via email to