Do you have a "local" address for yourself via OSA-ICC,9074, or something else? We have been known to deal with the long distance and busy ops this way: "shutdown reipl iplparms cons=0315" where 315 is my "local" session and then once you get the sapl screen put prompt cons=0315 So you have the whole thing yourself? When done, "xautolog operator on nnn" or just another "shutdown reipl" with the defaults. Marcy
"This message may contain confidential and/or privileged information. If you are not the addressee or authorized to receive this for the addressee, you must not use, copy, disclose, or take any action based on this message or any information herein. If you have received this message in error, please advise the sender immediately by reply e-mail and delete this message. Thank you for your cooperation." ________________________________ From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On Behalf Of Schuh, Richard Sent: Thursday, March 19, 2009 3:15 PM To: IBMVM@LISTSERV.UARK.EDU Subject: [IBMVM] SHUTDOWN REIPL Is there any way short of updating SYSTEM CONFIG and reordering the page volumes to coax SHUTDOWN REIPL to not automatically perform a warm start. Having to involve operators who are 3000 miles away, and normally very busy, in the process is sometimes difficult (paperwork) and time consuming. Having the capability of entering NOAUTO would sometimes be very convenient. Regards, Richard Schuh