Do you have a "local" address for yourself via OSA-ICC,9074, or
something else?
 
We have been known to deal with the long distance and busy ops this way:
 
"shutdown reipl iplparms cons=0315"    where 315 is my "local" session 
and then once you get the sapl screen put 
prompt cons=0315
 
So you have the whole thing yourself?
 
When done, "xautolog operator on nnn" or just another "shutdown reipl"
with the defaults.
 
 
Marcy 

"This message may contain confidential and/or privileged information. If
you are not the addressee or authorized to receive this for the
addressee, you must not use, copy, disclose, or take any action based on
this message or any information herein. If you have received this
message in error, please advise the sender immediately by reply e-mail
and delete this message. Thank you for your cooperation."

 

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Schuh, Richard
Sent: Thursday, March 19, 2009 3:15 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: [IBMVM] SHUTDOWN REIPL



Is there any way short of updating SYSTEM CONFIG and reordering the page
volumes to coax SHUTDOWN REIPL to not automatically perform a warm
start. Having to involve operators who are 3000 miles away, and normally
very busy, in the process is sometimes difficult (paperwork) and time
consuming. Having the capability of entering NOAUTO would sometimes be
very convenient.

Regards,
Richard Schuh 

Reply via email to