DDR, in this case, works with device addresses.  Since you are trying to
run DDR from MAINT, 127A has to be attached to MAINT.  Since this is
540RES, thus cp owned, you can't detach it. As the others have
suggested, use 123.  Edit your user directory and find USER MAINT,
scroll forward from that point and you'll see that 123 is associated via
and MDISK with 540RES, 122 with 540SPL, etc.

Steve

 

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Edward M Martin
Sent: Thursday, June 04, 2009 10:22 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: HCPDDR704E error attempting to copy res volume

 

Hello Bobby Bauer,

 

     Typically Maint has 540RES as 123 MR.  You should be able to link
to maint 123 127a RR.

Then redo your DDR.  

 

Ed Martin

Aultman Health Foundation

330-363-5050

ext 35050

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Bauer, Bobby (NIH/CIT) [E]
Sent: Thursday, June 04, 2009 10:14 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: HCPDDR704E error attempting to copy res volume

 

I'm attempting to clone our pilot VM system to a production lpar since
it looks like a couple of applications might actually have a real future
(a quiet hurray!). Attempting to copy the res volumes fails

 

q 127a                            

DASD 127A CP OWNED  540RES   83   

 

then

 

ddr

input   127A 3390 540RES                 

HCPDDR704E DEVICE 127A NOT OPERATIONAL   

 

 

Any suggestions would be helpful.

 

 

Bobby Bauer
Center for Information Technology
National Institutes of Health
Bethesda, MD 20892-5628
301-594-7474

Reply via email to