I use gateway to differentiate between home and DRsite because I need
the nodename to be the same. I use CP QUERY GATEWAY to get the value. It
is a CP variable.

/Tom Kern

Gentry, Stephen wrote:
> Does anyone use the Gateway option on the System_Identifier  parameter
> in the SYSTEM  CONFIG  file?  I’ve tried using it and can’t get it do
> what I thought it would do.  System identifier is coded below (the cpuid
> has been replaces with x’s  but it is filled in correctly in the sys
> config file).
> 
>     System_Identifier * xxxxxx  DRTEST   Gateway LLIC 
> 
>     System_Identifier_Default ZVMV5R40  Gateway LLIC 
> 
> When I issue the CP  ID  command  I get: 
> 
> ITTS01   AT DRTEST   VIA *        08/17/09 16:28:31 EDT      MONDAY
> 
> I expect to get:
> 
> ITTS01   AT LLIC   VIA  RSCS        08/17/09 16:28:31 EDT      MONDAY
> 
> I do get the expected results when I code the information in the 
> SYSTEM  NETID  file on the  S  drive
> 
> Is my thinking correct?
> 
> Thanks,
> 
> Steve