Hi, Ashwin.
When you formatted and allocated the DASD volume from z/OS, did you
specify the CPVOL attribute? That tell ICKDSF to creaet a "dummy" z/OS
style VTOC in cylinder 0 so that to z/OS, the DASD looks full.
Also, it's a good idea not to make any of the DASD volumes that z/VM has
marked as 'cpowned' available to the z/OS side.
DJ
On 06/21/2010 10:51 AM, Bhemidhi, Ashwin wrote:
Hello all,
I was adding a 2nd page volume LEPG2A (3390-3) to one of our newly
installed z/VM 6.1 and I accidentally formatted cylinder 0 PERM. We
are now getting alerts about "IEC606I VTOC INDEX DISABLED ON
5815,LEPG2A,142,00000000". The new Page volume is working on z/VM.
q alloc page EXTENT EXTENT TOTAL PAGES HIGH % VOLID RDEV
START END PAGES IN USE PAGE USED ------ ---- ----------
---------- ------ ------ ------ ---- LEPG1A 5814 1
3338 600840 0 0 0% LEPG2A 5815 1 3338
600840 0 0 0% ------ ------ ---- SUMMARY
1174K 0 0% USABLE 1174K
0 0%
All our DASD storage is managed from the MVS side and I am guessing
that it looks for the VTOC and alerts when it cannot find one. Can I
use ICKDSF to put a valid VTOC back on the DASD? Are there any
pointers on this subject that I can use to get more information on?
Does Device Support facility's user guide all the information that I
need to do the above.
Thank you, Ashwin Bhemidhi Texas Instruments Inc.
--
Dave Jones
V/Soft
www.vsoft-software.com
Houston, TX
281.578.7544