On Friday, 08/27/2010 at 03:18 EDT, "Frank M. Ramaekers" 
<framaek...@ailife.com> wrote:


> The error message description is less than hepful:
>
> REASON = X?0035? The Startlan function failed. This is most likely 
indicated by 
> RETCODE=E080.

The OSA/SF book, which has those error codes in it, says:

E080 A LAN connection could not be made, possibly for one of the following 
reasons:
The cable may not be present
The LAN may not be functioning
The port may have been disabled from the Support Element (SE) of the 
server 

This suggests that the NIC is not COUPLEd to the VSWITCH.   You need to 
issue 'cp q v nic aa0 details'.

Alan Altmark
z/VM Development
IBM Endicott