In the USER DIRECT

STDEVOPT LIBRARY CTL



On Tue, Sep 28, 2010 at 1:17 PM, KEETON Dave * SDC
<dave.kee...@state.or.us>wrote:

>  I wanted to post this to the list before opening an ETR with IBM.
>
> I have a 2nd-level 5.4 system I'm trying to set with DFSMS/VM's RMS
> component to talk to a virtual tape library. The drives are DEDICATED
> through the USER DIRECT entry. The system can SEE the drives as Tape drives
> when the devices are queried, but when RMS starts, it fails with the
> following errors:
>
> DMSACP723I D (192) R/O
> DMSACC724I 192 replaces D (192)
> DMSACP723I D (192) R/O
>
>  10:12:01  * MSG FROM RMSMASTR: DFSMS IS STARTING
>
> Name      Entry    Userword Origin   Bytes   Amode (Attributes)
> FSMDFSMS  01DDF988 00000000 01D88000 001A3368   31
> PIPE      01803712 01F665A0 01803712 00000000   31
> PIPMOD    01800000 01F665A0 01800000 0008F960   31  SYSTEM SERVICE
> IMMCMD
> DMSRTPRC  0179D9A0 00000000 0179D9A0 00040340   31
> SYSTEM
>  PERM
> DMSRTMSG  017DDCE0 00000000 017DDCE0 00000610   31
> SYSTEM
>  PERM
> NAMEFSYS  011D9460 01F61E58 011D9460 00000000   31  SYSTEM SERVICE
> NAMEFIND  011D9460 01FCE3A8 011D9460 00000000   31  SYSTEM SERVICE
> NAMEFUSE  011D9460 01F60E58 011D9460 00000000   31  SYSTEM SERVICE
> RXSOCKET  01897568 00000000 018973B8 00012A60   31  SYSTEM SERVICE
> DMSWRS    015FC218 00000000 015FC218 00003BD8   31  SYSTEM
>
> FSMBBV3053I All DFSMS local APPC/VM resources initialized
> FSMRMBLC==> Diag 254 is available
> TAPE 40CE ATTACHED TO RMSMASTR 40CE
> FSMBAC2006E Library I/O error; reason code = 3800, request identifier = 0,
> devic
> e = 40CE, library =
> FSMBAC2019E Sense Data =
> C0408027000000201000B320000000000000000040000000CE1F062
> 0F6290E00
> TAPE 40CE DETACHED BY RMSMASTR
> TAPE 40CF ATTACHED TO RMSMASTR 40CF
> FSMBBD2241W Device 40CE could not be initialized
> FSMBAC2006E Library I/O error; reason code = 3800, request identifier = 0,
> devic
> e = 40CF, library =
> FSMBAC2019E Sense Data =
> C0408027000000201000B320000000000000000040000000CE1F062
> 0F6290F00
> TAPE 40CF DETACHED BY RMSMASTR
> FSMBBD2241W Device 40CF could not be initialized
> FSMSMS3203I RMSMASTR is running
>
> When I look up the error FSMBAC2006E I don't find a lot of help.  :-(
>
> The RMCONFIG DATA file contains the two drive addresses, 40CE & 40CF.
>
> The DGTVCNTL DATA file contains the RM_AUTO_LIBRARY value it should to find
> the VTS.
>
> Any suggestions?
>
> Thanks,
> Dave
>



-- 
Mark D Pace
Senior Systems Engineer
Mainline Information Systems

Reply via email to