Thank you, Mark! I had the entry in the RMSMASTR on 2nd-level, but did
not realize I'd need it defined in the 2nd-level guest itself. The
errors are gone now.
 
Regards,
Dave

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Mark Pace
Sent: Tuesday, September 28, 2010 10:33 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: RMS Errors


In the USER DIRECT 

STDEVOPT LIBRARY CTL 



On Tue, Sep 28, 2010 at 1:17 PM, KEETON Dave * SDC
<dave.kee...@state.or.us> wrote:


        I wanted to post this to the list before opening an ETR with
IBM. 

        I have a 2nd-level 5.4 system I'm trying to set with DFSMS/VM's
RMS component to talk to a virtual tape library. The drives are
DEDICATED through the USER DIRECT entry. The system can SEE the drives
as Tape drives when the devices are queried, but when RMS starts, it
fails with the following errors:

        DMSACP723I D (192) R/O 
        DMSACC724I 192 replaces D (192) 
        DMSACP723I D (192) R/O 
          
         10:12:01  * MSG FROM RMSMASTR: DFSMS IS STARTING 
          
        Name      Entry    Userword Origin   Bytes   Amode (Attributes) 
        FSMDFSMS  01DDF988 00000000 01D88000 001A3368   31 
        PIPE      01803712 01F665A0 01803712 00000000   31 
        PIPMOD    01800000 01F665A0 01800000 0008F960   31  SYSTEM
SERVICE        IMMCMD 
        DMSRTPRC  0179D9A0 00000000 0179D9A0 00040340   31  SYSTEM

         PERM 
        DMSRTMSG  017DDCE0 00000000 017DDCE0 00000610   31  SYSTEM

         PERM 
        NAMEFSYS  011D9460 01F61E58 011D9460 00000000   31  SYSTEM
SERVICE 
        NAMEFIND  011D9460 01FCE3A8 011D9460 00000000   31  SYSTEM
SERVICE 
        NAMEFUSE  011D9460 01F60E58 011D9460 00000000   31  SYSTEM
SERVICE 
        RXSOCKET  01897568 00000000 018973B8 00012A60   31  SYSTEM
SERVICE 
        DMSWRS    015FC218 00000000 015FC218 00003BD8   31  SYSTEM 
          
        FSMBBV3053I All DFSMS local APPC/VM resources initialized 
        FSMRMBLC==> Diag 254 is available 
        TAPE 40CE ATTACHED TO RMSMASTR 40CE 
        FSMBAC2006E Library I/O error; reason code = 3800, request
identifier = 0, devic 
        e = 40CE, library = 
        FSMBAC2019E Sense Data =
C0408027000000201000B320000000000000000040000000CE1F062 
        0F6290E00 
        TAPE 40CE DETACHED BY RMSMASTR 
        TAPE 40CF ATTACHED TO RMSMASTR 40CF 
        FSMBBD2241W Device 40CE could not be initialized 
        FSMBAC2006E Library I/O error; reason code = 3800, request
identifier = 0, devic 
        e = 40CF, library = 
        FSMBAC2019E Sense Data =
C0408027000000201000B320000000000000000040000000CE1F062 
        0F6290F00 
        TAPE 40CF DETACHED BY RMSMASTR 
        FSMBBD2241W Device 40CF could not be initialized 
        FSMSMS3203I RMSMASTR is running 

        When I look up the error FSMBAC2006E I don't find a lot of help.
:-( 

        The RMCONFIG DATA file contains the two drive addresses, 40CE &
40CF. 

        The DGTVCNTL DATA file contains the RM_AUTO_LIBRARY value it
should to find the VTS. 

        Any suggestions? 

        Thanks, 
        Dave 




-- 

Mark D Pace 
Senior Systems Engineer 
Mainline Information Systems 




Reply via email to