Ah!  Us single CEC guys always forget about that!

I think I'll also look into IPGATE.

On Thu, Sep 30, 2010 at 11:47 AM, Alan Altmark <alan_altm...@us.ibm.com>wrote:

> On Thursday, 09/30/2010 at 11:23 EDT, Mark Pace <pacemainl...@gmail.com>
> wrote:
> > From the connectivity manual -
> > VM domain controllers must use channel-to-channel (CTC) links to be
> attached to
> > other VM domain controllers in the CS collection. The VM domain
> controllers may
> > be running ISFC or VM PWSCF to participate in the CS collection.
> >
> > Are these links ESCON CTC or FICON CTC - or does it matter?
>
> It doesn't mater.
>
> > Why doesn't ISFC take advantage of Hipersockets? You've got this high
> speed
> > "network" built in to System Z, seems odd that I have to use "old
> fashioned"
> > hardware connections.
>
> Because that wouldn't let you connect two CECs, and you already have
> FICON/ESCON infrastructure.
>
> Alan Altmark
>
> z/VM and Linux on System z Consultant
> IBM System Lab Services and Training
> ibm.com/systems/services/labservices
> office: 607.429.3323
> alan_altm...@us.ibm.com
> IBM Endicott
>



-- 