Ah, I wonder if it is a function of number of devices!  Prod has 1800+ DASD 
vols now, each with a PPRC secondary - so approx 3700 addresses.  That would 
explain why our tiny systems here have seen it too - they have access to the 
whole farm.  We'll see what Endicott says tomorrow I guess.  It looks like 16 
seconds of it is in the mystery step between processors offline and STEP USOAC. 
 There are 7 processors here though and 5 go offline, FWIW.

Thanks Dennis!



Marcy 
-----Original Message-----
From: The IBM z/VM Operating System [mailto:IBMVM@LISTSERV.UARK.EDU] On Behalf 
Of O'Brien, Dennis L
Sent: Thursday, June 23, 2011 4:33 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: [IBMVM] Question on SHUTDOWNTIME

I think I saw one of our systems take 78 seconds to shut down recently, but 
AFAIK, we don't have software to capture the shutdown messages.  If I'm 
thinking of the right system, it has over 5000 devices.

                                                                                
                                           Dennis O'Brien

"I want to express my gratitude to my family.  To my mother and father who 
instilled in me the values that have carried me this far."  -- former U.S. 
Representative Anthony Wiener, during his resignation speech

-----Original Message-----
From: The IBM z/VM Operating System [mailto:IBMVM@LISTSERV.UARK.EDU] On Behalf 
Of Marcy Cortes
Sent: Thursday, June 23, 2011 16:05
To: IBMVM@LISTSERV.UARK.EDU
Subject: [IBMVM] Question on SHUTDOWNTIME

The default is 30 seconds (Q SHUTDOWNTIME) for the CP's portion of the shutdown 
process.
I recall hearing that is good default.

We are seeing systems exceed that - 33 seconds in this one that seemed to come 
with bonus messages (that is our SW seemed to capture the HCPWRP963I's on this 
one).


Are others seeing that?  



Here's an example.

MZ8-300:Jun 18 23:56:00-SYSTEM   000%    49 Users  VM:Operator on 
OPERATOR(ME8VM)    Sun 19Jun11  01:56
               01:51:48 HCPSHU6018I The processor controller has sent a 
shutdown signal with a
               timeout interval of 300 seconds
               01:51:48 HCPSHU6019I Guests may not have time to shut down 
because VM SHUTDOWN
               requires 30 seconds
               01:51:48 HCPSIG2113I User VMSERVU has reported successful 
termination
               01:51:48 HCPSIG2113I User ME8SFS has reported successful 
termination
               01:52:18 HCPSIG2113I User ME8PROX2 has reported successful 
termination


MZ8-300:Jun 18 23:56:19-01:56:19 Processor 01 offline
MZ8-300:Jun 18 23:56:19-01:56:19 Processor 02 offline
MZ8-300:Jun 18 23:56:20-01:56:20 Processor 03 offline
MZ8-300:Jun 18 23:56:20-01:56:20 Processor 04 offline
MZ8-300:Jun 18 23:56:21-01:56:21 Processor 05 offline
MZ8-300:Jun 18 23:56:37- 01:56:37 HCPWRP963I SHUTDOWN STEP USOAC - JOURNAL USER 
TERMINATION
MZ8-300:Jun 18 23:56:38- 01:56:38 HCPWRP963I SHUTDOWN STEP MFRSD - TERMINATE 
HARDWARE LOADER
MZ8-300:Jun 18 23:56:38- 01:56:38 HCPWRP963I SHUTDOWN STEP APISD - TERMINATE 
OTHER PROCESSORS
MZ8-300:Jun 18 23:56:39- 01:56:39 HCPWRP963I SHUTDOWN STEP ENASD - DISABLE 
TERMINAL DEVICES
MZ8-300:Jun 18 23:56:40- 01:56:39 HCPWRP963I SHUTDOWN STEP XLGIN - CLEAR 
CROSS-SYSTEM LINK FLAGS
MZ8-300:Jun 18 23:56:40- 01:56:40 HCPWRP963I SHUTDOWN STEP ISHDN - SHUT DOWN 
I/O SUBSYSTEM
MZ8-300:Jun 18 23:56:41- 01:56:41 HCPWRP963I SHUTDOWN STEP SVACV - ACTIVATE 
TERMINATION SAVE AREAS
MZ8-300:Jun 18 23:56:41- 01:56:41 HCPWRP963I SHUTDOWN STEP MXYTM - STOP CHANNEL 
PATH MEASUREMENT FACILIT
                
MZ8-300:Jun 18 23:56:42- 01:56:42 HCPWRP963I SHUTDOWN STEP CHMOF - DISABLE 
CHANNEL MEASUREMENT
MZ8-300:Jun 18 23:56:43- 01:56:42 HCPWRP963I SHUTDOWN STEP ISHDA - DISABLE ALL 
DEVICES
MZ8-300:Jun 18 23:56:48- 01:56:47 HCPWRP963I SHUTDOWN STEP CKPSH - TAKE A 
CHECKPOINT
MZ8-300:Jun 18 23:56:49- 01:56:49 HCPWRP963I SHUTDOWN STEP OPRCK - SAVE 
OPERATOR CONSOLE LIST
MZ8-300:Jun 18 23:56:50- 01:56:49 HCPWRP963I SHUTDOWN STEP MCWMD - DETERMINE 
MACHINE CHECK STATUS
MZ8-300:Jun 18 23:56:50- 01:56:50 HCPWRP963I SHUTDOWN STEP SDVRS - RESET IBM 
DASD CU CHARACTERISTICS
MZ8-300:Jun 18 23:56:51- 
                
                
                
                
                
                HCPWRP962I VM SHUTDOWN COMPLETED IN 33 SEC
                01:56:51 HCPWRP963I SHUTDOWN STEP SVADV - DEACTIVATE 
TERMINATION SAVE AREAS
                
                
                
                
                
                
                HCPWRP962I VM SHUTDOWN COMPLETED IN 33 SEC
MZ8-300:Jun 18 23:56:52- 01:56:51 HCPWRP961W SYSTEM SHUTDOWN COMPLETE





Marcy 

----------------------------------------------------------------------
This message w/attachments (message) is intended solely for the use of the 
intended recipient(s) and may contain information that is privileged, 
confidential or proprietary. If you are not an intended recipient, please 
notify the sender, and then please delete and destroy all copies and 
attachments, and be advised that any review or dissemination of, or the taking 
of any action in reliance on, the information contained in or attached to this 
message is prohibited. 
Unless specifically indicated, this message is not an offer to sell or a 
solicitation of any investment products or other financial product or service, 
an official confirmation of any transaction, or an official statement of 
Sender. Subject to applicable law, Sender may intercept, monitor, review and 
retain e-communications (EC) traveling through its networks/systems and may 
produce any such EC to regulators, law enforcement, in litigation and as 
required by law. 
The laws of the country of each sender/recipient may impact the handling of EC, 
and EC may be archived, supervised and produced in countries other than the 
country in which you are located. This message cannot be guaranteed to be 
secure or free of errors or viruses. 

References to "Sender" are references to any subsidiary of Bank of America 
Corporation. Securities and Insurance Products: * Are Not FDIC Insured * Are 
Not Bank Guaranteed * May Lose Value * Are Not a Bank Deposit * Are Not a 
Condition to Any Banking Service or Activity * Are Not Insured by Any Federal 
Government Agency. Attachments that are part of this EC may have additional 
important disclosures and disclaimers, which you should read. This message is 
subject to terms available at the following link: 
http://www.bankofamerica.com/emaildisclaimer. By messaging with Sender you 
consent to the foregoing.

Reply via email to