> On 28 Jun 2016, at 12:45, Ilott, Ross <[email protected]> wrote: > > I have a simple HA setup as follows: > > Object Endpoint “icinga1” { host = “icinga1” } > Object Endpoint “icinga2 { host = “icinga2” } > Object Endpoint “icinga3” { host = “icinga3” } > > Object Zone “A” { > Endpoints = [ “icinga1”, “icinga2” ] > } > > Object Zone “B” { > Endpoints = [ “icinga3” ] > Parent = “A” > } > > icinga3 is just a satellite checker node, executing checks. > > What happens to the checks that icinga3 is executing if zone B is no longer > visible to zone A? > Can zone A take over responsibility for these checks after some kind of > timeout?
No, these checkable objects are assigned to that specific zone B. Although if you are using the cluster config sync the satellite node in zone B will continue the checks on its own and once reconnected the replay log ensures to keep the history on the master zone A in sync. Cheers from the Icinga Director talk at Icinga Camp Amsterdam, Michael > > Generally looking for any designs which might make all checks failover to > zone A in the case that zone B dies! > > Thanks , > Ross > This email and any files transmitted with it contain confidential, privileged > and/or proprietary information and is solely for the use of the intended > recipient. If you are not the intended recipient please return the email to > the sender and delete it from your computer and you must not use, disclose, > distribute, copy, print or rely on this email or its contents. This > communication is for informational purposes only. It is not intended as an > offer or solicitation for the purchase or sale of any financial instrument or > as an official confirmation of any transaction. Any comments or statements > made herein do not necessarily reflect those of XTX. XTX Markets Limited is > registered in England and Wales at Leconfield House, Curzon Street, London > W1J 5JA, number 09415174. XTX Research LLP is registered in England and Wales > at the same address, number OC397853. > > _______________________________________________ > icinga-users mailing list > [email protected] > https://lists.icinga.org/mailman/listinfo/icinga-users -- Michael Friedrich, DI (FH) Senior Developer NETWAYS GmbH | Deutschherrnstr. 15-19 | D-90429 Nuernberg Tel: +49 911 92885-0 | Fax: +49 911 92885-77 CEO: Julian Hein, Bernd Erk | AG Nuernberg HRB18461 http://www.netways.de | [email protected] ** OSBConf 2016 - September - osbconf.org ** ** OSMC 2016 - November - netways.de/osmc ** _______________________________________________ icinga-users mailing list [email protected] https://lists.icinga.org/mailman/listinfo/icinga-users