On Wednesday 03 February 2010 12:06:15 pm 康明亮 wrote: > Dear, I want to ask why the exported Chi(K) file from Artermis can not > repeat the figure like in Graphic window #1 - [Athena]. I planed to output > the fitted data from Artemis and plot in Origin 8.0 or Excel ect, but the > figure based on the output data seems strange for Chi(K) file. For Chi(R), > it was ok, the shape plotted in Origin 8.0 was the same like in Graphic > window #1 - [Athena]. I do not know why?In addition, I want to ask a > question about Artermis fitting. I used 5 paths for fitting, and it seemed > a good fitting from the figure in Graphic window #1 - [Athena]. But the > results showed that only path 1 had good values of N, R-factor, > Chi-square, amp and sigma^2. If I choose only path 1 for fitting, the > figure in Graphic window #1 - [Athena] showed only the highest peak fitted > perfectly. Thus, I am not sure how many path that I should choose for > fitting(I know only path 1 is available). The problem is, how can I export > the fitted results, with or without ohter paths? Tha! nks!Best > wishes
Mingliang Rather than repeat what I said before, I will give you a link and let you re-read it: http://millenia.cars.aps.anl.gov/pipermail/ifeffit/2010-January/009273.html B PS. One more hint: asking clear, easy-to-understand is one of the good reasons that Athena and Artemis give you the option of saving project files. -- Bruce Ravel ------------------------------------ bra...@bnl.gov National Institute of Standards and Technology Synchrotron Methods Group at NSLS --- Beamlines U7A, X24A, X23A2 Building 535A Upton NY, 11973 My homepage: http://xafs.org/BruceRavel EXAFS software: http://cars9.uchicago.edu/~ravel/software/exafs/ _______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit