Dear Michaels,

I've just written off-list to Gabriel with the same conclusion and the
attached image. In short, the effect is in fact a consequence of the
"Legacy"-scheme.

Best

Herbie

::::::::::::::::::::::::::::::::::::::::::::
Am 04.07.25 um 11:39 schrieb Michael Schmid:
> Hi Michael,
>
> the reason for the problem is the following:
> The wand starts from the image center and then goes to the right until
> it finds an edge of the thresholded region. In the
> 'wand_tool_does_not_work' file it finds an inner hole (one pixel not
> thresholded) and thresholds that single pixel.
>
> You can avoid this by using wand mode '8-connected' instead of the
> default (legacy mode).
>      doWand(getWidth/2, getHeight/2, 0, "8-connected");
> 8-connected mode is also more robust in some other aspects.
> Don't care about the tolerance value (3rd argument, here set to 0), it
> is ignored for thresholded images.
>
>
> Michael
> ________________________________________________________________
> On 03.07.25 18:38, Cammer, Michael wrote:
>>
>> I posted images at
>> https://urldefense.com/v3/__https://microscopynotes.com/temp/wand_tool_works.png__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhx8bpzk0$<https://urldefense.com/v3/__https:/microscopynotes.com/temp/wand_tool_works.png__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhx8bpzk0$>
>> https://urldefense.com/v3/__https://microscopynotes.com/temp/wand_tool_does_not_work.png__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhMgLRplk$<https://urldefense.com/v3/__https:/microscopynotes.com/temp/wand_tool_does_not_work.png__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhMgLRplk$>
>>
>> The following code always works when the run("Median...", "radius=2");
>> is run.
>> But looking at the image that does not work, I don't see a single
>> pixel near getWidth/2, getHeight/2 which does not fall withing the
>> threshold range.
>>
>> Cheers-
>> Michael
>>
>>
>>     run("Select None");
>>     run("8-bit");
>>     //run("Median...", "radius=2");
>>     setAutoThreshold("Default no-reset");
>>     getThreshold(min, max);
>>     max = max * 1.25;            // grab additional periphery which
>> may be thin and light
>>     setThreshold(0, max, "raw");
>>     doWand(getWidth/2, getHeight/2);
>>     run("Set Measurements...", "area display redirect=None decimal=2");
>>     run("Measure");
>>     print(getTitle + "\t  " + getResult("Area") + "\t pixels -- result
>> really should be reported as um^2");
>>     selectWindow("Log");
>>
>>
>>
>> -----Original Message-----
>> From: Gluender <[email protected]>
>> Sent: Thursday, July 3, 2025 9:56 AM
>> To: [email protected]
>> Subject: Re: help with wand tool
>>
>> [EXTERNAL]
>>
>> Greetings Michael,
>>
>> do have images to test?
>>
>> Best
>>
>> Herbie
>>
>> :::::::::::::::::::::::::::::::::::::::::::::
>> Am 03.07.25 um 15:48 schrieb Cammer, Michael:
>>> We have images where there is dark object at the center of the field
>>> that we want to measure.  We are very puzzled because the following
>>> code works for some images and not for others.  When we manually
>>> click using the wand tool, it always works, but this code only works
>>> on some images and not others.
>>>
>>> We are using ImageJ 1.54q14  with java 1.8.0_172.
>>>
>>> Help would be appreciated.  Thank you!
>>>
>>>                   // This only reports area.  Best fitting ellipse or
>>> other morphometrics could be reported.
>>>                   run("Select None");
>>>                   run("8-bit");
>>>                   setAutoThreshold("Default no-reset");
>>>                   getThreshold(min, max);
>>>                   max = max *
>>> 1.25;                                           // grab additional
>>> periphery which may be thin and light
>>>                   setThreshold(0, max, "raw");
>>>                   doWand(getWidth/2, getHeight/2);
>>>                   run("Set Measurements...", "area display
>>> redirect=None decimal=2");
>>>                   run("Measure");
>>>                   print(getTitle + "\t  " + getResult("Area") + "\t
>>> pixels -- result really should be reported as um^2");
>>>                   selectWindow("Log");
>>>
>>> Michael Cammer, Sr Research Scientist, DART Microscopy Laboratory NYU
>>> Langone Health, 540 First Avenue, New York, NY  10016
>>> Office: RB (formerly Skirball) 4-102  -- call if door is locked (phone
>>> near elevators)
>>> Office: 646-501-0567 Cell (voice only, not text): 914-309-3270
>>> [email protected]<mailto:[email protected]>
>>> https://urldefense.com/v3/__http://nyulmc.org/micros__;!!MXfaZl3l!ZXZzBOssOTsy1L_yBR01V3HlavHaYYXIQsn6k_-gmg0nJ1i0f77fj1Ji4siraz3ftIUS7LOL6rDlOCJeaXfxFlo$<https://urldefense.com/v3/__http:/nyulmc.org/micros__;!!MXfaZl3l!ZXZzBOssOTsy1L_yBR01V3HlavHaYYXIQsn6k_-gmg0nJ1i0f77fj1Ji4siraz3ftIUS7LOL6rDlOCJeaXfxFlo$>
>>> https://urldefense.com/v3/__http://microscopynotes.com/__;!!MXfaZl3l!ZXZzBOssOTsy1L_yBR01V3HlavHaYYXIQsn6k_-gmg0nJ1i0f77fj1Ji4siraz3ftIUS7LOL6rDlOCJeYipsd6Y$<https://urldefense.com/v3/__http:/microscopynotes.com/__;!!MXfaZl3l!ZXZzBOssOTsy1L_yBR01V3HlavHaYYXIQsn6k_-gmg0nJ1i0f77fj1Ji4siraz3ftIUS7LOL6rDlOCJeYipsd6Y$>
>>>
>>> Scheduling the time you want is far more reliable by phone call.  Why
>>> not provide your phone number?
>>
>>
>> ------------------------------------------------------------
>> This email message, including any attachments, is for the sole use of
>> the intended recipient(s) and may contain information that is
>> proprietary, confidential, and exempt from disclosure under applicable
>> law. Any unauthorized review, use, disclosure, or distribution is
>> prohibited. If you have received this email in error please notify the
>> sender by return email and delete the original message. Please note,
>> the recipient should check this email and any attachments for the
>> presence of viruses. The organization accepts no liability for any
>> damage caused by any virus transmitted by this email.
>> =================================
>>
>>
>> --
>> ImageJ mailing list: 
>> https://urldefense.com/v3/__http://imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$<https://urldefense.com/v3/__http:/imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$>
>
> --
> ImageJ mailing list: 
> https://urldefense.com/v3/__http://imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$<https://urldefense.com/v3/__http:/imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$>


--
ImageJ mailing list: 
https://urldefense.com/v3/__http://imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$<https://urldefense.com/v3/__http:/imagej.nih.gov/ij/list.html__;!!MXfaZl3l!eEzWGltT2QAWZ3YqHOaAtS2wuA6lWAK6E15K1lXDLS9LcSeUpj_i6TryUDDGnptCcsoPN_kApTc7qJkhoD9qS5E$>

------------------------------------------------------------
This email message, including any attachments, is for the sole use of the 
intended recipient(s) and may contain information that is proprietary, 
confidential, and exempt from disclosure under applicable law. Any unauthorized 
review, use, disclosure, or distribution is prohibited. If you have received 
this email in error please notify the sender by return email and delete the 
original message. Please note, the recipient should check this email and any 
attachments for the presence of viruses. The organization accepts no liability 
for any damage caused by any virus transmitted by this email.
=================================

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html

Reply via email to