https://issues.apache.org/jira/browse/DRILL-4373?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15608480#comment-15608480
 ] 

ASF GitHub Bot commented on DRILL-4373:
---------------------------------------

Github user vdiravka commented on a diff in the pull request:

    https://github.com/apache/drill/pull/600#discussion_r85124582
  
    --- Diff: 
exec/java-exec/src/test/java/org/apache/drill/exec/physical/impl/writer/TestParquetWriter.java
 ---
    @@ -739,30 +739,54 @@ public void runTestAndValidate(String selection, 
String validationSelection, Str
       }
     
       /*
    -  Test the reading of an int96 field. Impala encodes timestamps as int96 
fields
    +    Impala encodes timestamp values as int96 fields. Test the reading of 
an int96 field with two converters:
    +    the first one converts parquet INT96 into drill VARBINARY and the 
second one (works while
    +    store.parquet.reader.int96_as_timestamp option is enabled) converts 
parquet INT96 into drill TIMESTAMP.
        */
       @Test
       public void testImpalaParquetInt96() throws Exception {
         compareParquetReadersColumnar("field_impala_ts", 
"cp.`parquet/int96_impala_1.parquet`");
    +    try {
    +      test("alter session set %s = true", 
ExecConstants.PARQUET_READER_INT96_AS_TIMESTAMP);
    +      compareParquetReadersColumnar("field_impala_ts", 
"cp.`parquet/int96_impala_1.parquet`");
    --- End diff --
    
    The above comment was addressed to the 
[testImpalaParquetBinaryAsTimeStamp_DictChange](https://github.com/apache/drill/pull/600/commits/81c48c9cd5cdc3905ea78c6cad07a9d818d5026f#diff-aab74a5027942e775c846cebc06c32a4R771)
 method
    
    
    Test was updated:
    An old incorrect file int96_dict_change.parquet was replaced with the new 
two ones with int96 timestamp field and different encoded pages (dictionary and 
non-dictionary).
    Csv baseline file also was added.


> Drill and Hive have incompatible timestamp representations in parquet
> ---------------------------------------------------------------------
>
>                 Key: DRILL-4373
>                 URL: https://issues.apache.org/jira/browse/DRILL-4373
>             Project: Apache Drill
>          Issue Type: Improvement
>          Components: Storage - Hive, Storage - Parquet
>    Affects Versions: 1.8.0
>            Reporter: Rahul Challapalli
>            Assignee: Karthikeyan Manivannan
>              Labels: doc-impacting
>             Fix For: 1.9.0
>
>
> git.commit.id.abbrev=83d460c
> I created a parquet file with a timestamp type using Drill. Now if I define a 
> hive table on top of the parquet file and use "timestamp" as the column type, 
> drill fails to read the hive table through the hive storage plugin
> Implementation: 
> Added int96 to timestamp converter for both parquet readers and controling it 
> by system / session option "store.parquet.int96_as_timestamp".
> The value of the option is false by default for the proper work of the old 
> query scripts with the "convert_from TIMESTAMP_IMPALA" function.
> When the option is true using of that function is unnesessary and can lead to 
> the query fail.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to