Pavel Tupitsyn created IGNITE-3512: -------------------------------------- Summary: .NET: IBinaryObject.ToBuilder loses type name Key: IGNITE-3512 URL: https://issues.apache.org/jira/browse/IGNITE-3512 Project: Ignite Issue Type: Bug Components: platforms Affects Versions: 1.5.0.final Reporter: Pavel Tupitsyn Assignee: Pavel Tupitsyn Fix For: 1.7
Steps to reproduce: * Create a builder for a string type name, set field, put to cache * On another node, read this object, call ToBuilder, call Build Type name is not propagated with metadata, which leads to assertion error (with -ea) or "Two binary types have duplicate type ID [typeId=949122880, typeName1=Security, typeName2=null]]" error. Unit test: {code} [Test] public void Test() { using (var grid1 = Ignition.Start(TestUtils.GetTestConfiguration())) using (var grid2 = Ignition.Start(new IgniteConfiguration(TestUtils.GetTestConfiguration(false)) {GridName = "grid2"})) { var cache1 = grid1.CreateCache<int, int>("cache").WithKeepBinary<int, IBinaryObject>(); var obj1 = grid1.GetBinary().GetBuilder("myType").SetField("myField", "val").Build(); cache1[1] = obj1; var cache2 = grid2.GetCache<int, int>("cache").WithKeepBinary<int, IBinaryObject>(); var obj2 = cache2[1]; var val = obj2.GetField<string>("myField"); var obj2Ex = grid2.GetBinary().GetBuilder(obj2).SetField("myField", val + "_modified").Build(); cache2[2] = obj2Ex; } } {code} -- This message was sent by Atlassian JIRA (v6.3.4#6332)