hi, RS-BIP8 is the Regenerator Section B1 Byte to provide end-to-end performance monitoring on a single regenerator section.
MS-BIP24 is the Multiplex Section B2 Bytes to provide error monitoring on the multiplex section. MS-FEBE is the Multiplex Section Far End Block Error (aka Remote Error Indication - REI) which is returned in response to receiving MS-BIP. Rgds, Guy On 07/06/07, snort bsd <[EMAIL PROTECTED]> wrote: > hi all: > > i have some questions regarding some parameters of > sonet/sdh: > > 1) what is RS-BIP8 > 2) what is MS-BIP24 > 3) what is MS-FEBE > > i found an old post from marcin; he really explained > the HP-FEBE and HP-BIP8 very well. it would be great > if some can also give out sources for those > parameters. > > thanks all > > > > _________________________________________________________________________________ > > How would you spend $50,000 to create a more sustainable environment in > Australia? Go to Yahoo!7 Answers and share your idea. > http://advision.webevents.yahoo.com/aunz/lifestyle/answers/y7ans-babp_reg.html > > > > _______________________________________________ > juniper-nsp mailing list juniper-nsp@puck.nether.net > https://puck.nether.net/mailman/listinfo/juniper-nsp > _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp