hi,

RS-BIP8 is the Regenerator Section B1 Byte to provide end-to-end
performance monitoring on a single regenerator section.

MS-BIP24 is the Multiplex Section B2 Bytes to provide error monitoring
on the multiplex section.

MS-FEBE is the Multiplex Section Far End Block Error (aka Remote Error
Indication - REI) which is returned in response to receiving MS-BIP.

Rgds,