You could also take a quick look at http://www.tek.com/Measurement/App_Notes/sdhprimer/anomalies.pdf which gives some useful info on SDH anomalies.
Rgds, Guy On 07/06/07, Guy Davies <[EMAIL PROTECTED]> wrote: > hi, > > RS-BIP8 is the Regenerator Section B1 Byte to provide end-to-end > performance monitoring on a single regenerator section. > > MS-BIP24 is the Multiplex Section B2 Bytes to provide error monitoring > on the multiplex section. > > MS-FEBE is the Multiplex Section Far End Block Error (aka Remote Error > Indication - REI) which is returned in response to receiving MS-BIP. > > Rgds, > > Guy > > On 07/06/07, snort bsd <[EMAIL PROTECTED]> wrote: > > hi all: > > > > i have some questions regarding some parameters of > > sonet/sdh: > > > > 1) what is RS-BIP8 > > 2) what is MS-BIP24 > > 3) what is MS-FEBE > > > > i found an old post from marcin; he really explained > > the HP-FEBE and HP-BIP8 very well. it would be great > > if some can also give out sources for those > > parameters. > > > > thanks all > > > > > > > > _________________________________________________________________________________ > > > > How would you spend $50,000 to create a more sustainable environment in > > Australia? Go to Yahoo!7 Answers and share your idea. > > http://advision.webevents.yahoo.com/aunz/lifestyle/answers/y7ans-babp_reg.html > > > > > > > > _______________________________________________ > > juniper-nsp mailing list juniper-nsp@puck.nether.net > > https://puck.nether.net/mailman/listinfo/juniper-nsp > > > _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp