If you need heavy sampling then using service PIC/monitoring PIC is the option that you can choose. If you use a service PIC/monitoring PIC, the sampled packets don't go into RE-PFE link but handled by the PICs with higher performance.
Regards, Sungro -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Tinka Sent: Tuesday, October 02, 2007 1:59 PM To: juniper-nsp@puck.nether.net Subject: [j-nsp] cflowd Export Issue Hello all. Got this error earlier today: # commit [edit forwarding-options sampling output cflowd n.n.n.n] cflowd configuration error Can not configure more than one cflowd v5 collector Google'ing further suggests that because the internal RE-PFE link is only a 100Mbps Fast-E connection, there is potential to choke other control traffic if multiple flows of the same cflowd version are exported to a collector. Most of the M-series platforms seem to have this design. Any workaround? Cheers, Mark. _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp