I think Juniper has no equivalent command for "shut down" like in Cisco but
I do know that if disable the port the router will not be able to send
traffic to that interface and will ignore all command related to that
interface although, the remote peer will still see the port up.

On Wed, Mar 5, 2008 at 12:55 AM, Samuel <[EMAIL PROTECTED]> wrote:

>
> > The following commands should do the trick on M7i,
> > regardless of the fact that interface is fixed.
> > Be careful, though, your second port fe-1/3/1 will be shut-down as well.
> > request chassis pic offline fpc-slot 1 pic-slot 3
> Thanks Alexander. I had tried, but too quickly. It works fine even on
> fixed interfaces.
>
>
> Timo, if I use: "set interface fa-x/y/z disable", I get it:
>
> [EMAIL PROTECTED]> show interfaces terse
> Interface               Admin  Link     Proto    Local
> Remote
> fe-1/3/0                down   up
>
> Hyun, if I use: "deactivate interface fa-0/0/0", I get it:
>
> [EMAIL PROTECTED]> show interfaces terse
> Interface               Admin  Link     Proto    Local
> Remote
> fe-1/3/0                up     up
>
> And I would like to get:
> fe-1/3/0                down   down
>
>
>
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to