> > Yes, we run the 20 x GE with tunnel. > > > > FPC 0 REV 14 DPCE 20x 1GE R EQ > > I'm not sure if that's the same card, the DPCE-R-20GE-2XGE has 2x 10GbE > in addition to 20 x GbE. I think you might have the DPCE-R-Q-20GE-SFP?
It's not the same card. But the *principle* still holds. > But in any case I think they're likely to work the same. Thanks for > your reply! > > > fpc 0 { > > pic 1 { > > tunnel-services { > > bandwidth 1g; > > > > Interface will be: ip-0/1/10 > > Interesting. So you're still able to use all physical ports (ge-0/1/0 > through ge-0/1/9) as before; you've actually oversubscribed the PFE by > 11:10? The PFE has enough capacity for the extra 1 Gig tunnel, it is *not* oversubscribed with 1 tunnel port in use. > That can't be done on the 10 GbE PFE, enabling tunnel services > deactivates the physical port completely. :-( We know. So far we have only used 1 Gig tunnel ports. Steinar Haug, Nethelp consulting, sth...@nethelp.no _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp