Hello,

I am currently looking into an issue where we are getting temperature alerts on 
a variety of different JunOS devices within one of our facilities. 
Unfortunately when I go to track down the changes all the switches are running 
at under 40c which is within the thresholds yet we still get alerts. 

jstew...@junos Switch> show chassis temperature-thresholds 
                           Fan speed        Yellow alarm         Red alarm
Item                     Normal   High    Normal   Bad fan    Normal   Bad fan
FPC 0 CPU                    60     70        80        70        95        85
FPC 0 EX-PFE1                60     70        80        70        95        85
FPC 0 EX-PFE2                60     70        80        70        95        85
FPC 0 EX-PFE3                60     70        80        70        95        85
FPC 0 GEPHY Front Left       60     70        80        70        95        85
FPC 0 GEPHY Front Middle     60     70        80        70        95        85
FPC 0 GEPHY Front Right      60     70        80        70        95        85
FPC 0 Uplink Conn            60     70        80        70        95        85

{master:0}
jstew...@junos Switch> show chassis environment 
Class Item                           Status     Measurement
Power FPC 0 Power Supply 0           OK        
      FPC 0 Power Supply 1           OK        
Temp  FPC 0 CPU                      OK         38 degrees C / 100 degrees F
      FPC 0 EX-PFE1                  OK         39 degrees C / 102 degrees F
      FPC 0 EX-PFE2                  OK         50 degrees C / 122 degrees F
      FPC 0 EX-PFE3                  OK         45 degrees C / 113 degrees F
      FPC 0 GEPHY Front Left         OK         20 degrees C / 68 degrees F
      FPC 0 GEPHY Front Middle       OK         27 degrees C / 80 degrees F
      FPC 0 GEPHY Front Right        OK         29 degrees C / 84 degrees F
      FPC 0 Uplink Conn              OK         28 degrees C / 82 degrees F
Fans  FPC 0 Fan 1                    OK         Spinning at normal speed
      FPC 0 Fan 2                    OK         Spinning at normal speed
      FPC 0 Fan 3                    OK         Spinning at normal speed

{master:0}

jstew...@junos Switch> show chassis alarms 
No alarms currently active

I am interested to know if anyone has anything similar? Also is it possible to 
set the thresholds?

Regards,

Jimmy Stewpot
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp