This sets a sampling rate of 128:1. Is that intentional? yes. i want samples of a every 128 packets
i have also tried with 100 and 512 but still same output. Op wo 2 jan. 2019 om 11:16 schreef Dave Bell <m...@geordish.org>: > set forwarding-options sampling instance inline input rate 128 > > This sets a sampling rate of 128:1. Is that intentional? > > Dave > > On Wed, 2 Jan 2019 at 10:08, A. Camci <avciguz...@gmail.com> wrote: > >> Hi Steinar, >> >> see the config: >> >> set services flow-monitoring version-ipfix template ipv4 ipv4-template >> set services flow-monitoring version-ipfix template ipv6 ipv6-template >> >> >> set forwarding-options sampling instance inline input rate 128 >> set forwarding-options sampling instance inline family inet output >> flow-server xx.xx.10.34 port 2055 >> set forwarding-options sampling instance inline family inet output >> flow-server xx.xx.10.34 version-ipfix template ipv4 >> set forwarding-options sampling instance inline family inet output >> inline-jflow source-address xx.xx.0.238 >> >> set forwarding-options sampling instance inline family inet6 output >> flow-server xx.xx.10.34 port 2055 >> set forwarding-options sampling instance inline family inet6 output >> flow-server xx.xx.10.34 version-ipfix template ipv6 >> set forwarding-options sampling instance inline family inet6 output >> inline-jflow source-address xx.xx.0.238 >> >> set chassis fpc 0 sampling-instance inline >> set forwarding-options sampling instance inline family inet output >> flow-server xx.xx.10.34 version-ipfix template ipv4 >> set forwarding-options sampling instance inline family inet6 output >> flow-server xx.xx.10.34 version-ipfix template ipv6 >> set protocols bgp group fulltable-2-genie neighbor xx.xx.10.34 >> >> set interfaces ae0 unit 0 family inet sampling input >> set interfaces ae0 unit 0 family inet6 sampling input >> set interfaces ae1 unit 0 family inet sampling input >> set interfaces ae1 unit 0 family inet6 sampling input >> set interfaces ae5 unit 0 family inet sampling input >> set interfaces ae5 unit 0 family inet6 sampling input >> >> >> is a reboot necessary after the configuration ? >> >> thanks >> ap >> >> Op wo 2 jan. 2019 om 10:56 schreef <sth...@nethelp.no>: >> >> > > Does anyone have experience with GENIEATM ( 6.3.2 ) and Juniper MX480 >> > MPCE >> > > Type 2 3D ( 16.1R4-S3.6). >> > > recently we use the inline-jflow monitoring. >> > > >> > > it works but we receive too little sampling. >> > > expect a 10k of sampling per second instead of 100 samples >> > >> > We have quite a bit of experience with inline-jflow/IPFIX. It mostly >> > works just fine. Show your JunOS config, please. >> > >> > Steinar Haug, Nethelp consulting, sth...@nethelp.no >> > >> _______________________________________________ >> juniper-nsp mailing list juniper-nsp@puck.nether.net >> https://puck.nether.net/mailman/listinfo/juniper-nsp >> > _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp