https://bugs.kde.org/show_bug.cgi?id=514227
Bug ID: 514227
Summary: KDE Partition Manager not showing SMART info correctly
Classification: Applications
Product: partitionmanager
Version First 25.12.0
Reported In:
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
Target Milestone: ---
Created attachment 188268
--> https://bugs.kde.org/attachment.cgi?id=188268&action=edit
screenshot of part of the partition manager screen showing the wrong info
SUMMARY
STEPS TO REPRODUCE
1. open partition manager;
2. in the "devices" section right click the name of the ssd
3. Select SMART Status
OBSERVED RESULT
Kde shows the temp of the drive being -273, although it reports the disk as
being healthy.
No further SMART properties are being shown
EXPECTED RESULT
SMART info as smartctl reports it:
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.12.63-1-lts] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: WD PC SN5000S SDEPNSJ-512G-1001
Serial Number: 252440401497
Firmware Version: 34250001
PCI Vendor/Subsystem ID: 0x15b7
IEEE OUI Identifier: 0x001b44
Total NVM Capacity: 512.110.190.592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 2.0
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512.110.190.592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 001b44 4a458199c9
Local Time is: Tue Jan 6 15:08:56 2026 CET
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x00df): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Timestmp Verify
Log Page Attributes (0x7e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Log0_FISE_MI Telmtry_Ar_4
Maximum Data Transfer Size: 128 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 92 Celsius
Namespace 1 Features (0x92): NA_Fields NP_Fields *Other*
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 3.00W 3.00W - 0 0 0 0 0 0
2 + 2.50W 2.50W - 0 0 0 0 0 0
3 - 0.0200W - - 3 3 3 3 2000 3000
4 - 0.0050W - - 4 4 4 4 4000 12000
5 - 0.0030W - - 5 5 5 5 176000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning: 0x00
Temperature: 21 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 3.247.935 [1,66 TB]
Data Units Written: 743.893 [380 GB]
Host Read Commands: 8.786.706
Host Write Commands: 8.597.295
Controller Busy Time: 39
Power Cycles: 63
Power On Hours: 18
Unsafe Shutdowns: 2
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 20 Celsius
Temperature Sensor 2: 21 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
SOFTWARE/OS VERSIONS
Windows:
macOS:
(available in the Info Center app, or by running `kinfo` in a terminal window)
Linux/KDE Plasma:
KDE Plasma Version:
KDE Frameworks Version:
Qt Version:
ADDITIONAL INFORMATION
--
You are receiving this mail because:
You are watching all bug changes.