60617-3 allows a dotless junction (as in 03-02-06), but the same connection can be represented with two 03-02-05; it is not a violation of the standard to always use dots.
On Mon, Jun 08, 2015 at 08:48:12AM +0300, Vesa Solonen wrote: > 08/06/15, 00:44, Wayne Stambaugh kirjoitti: > > One thing I did notice is that bus entries do not draw the connection > > point so they cannot show their connection status. It would be nice if > > bus entries exhibited the same behavior. I'm not sure how much work > > would be involved. I'm surprised I never noticed that before or AFAIR > > no one has every said anything about it. > > Are you guys aware that to support both options in EN 60617-3 (1997) > [symbols 03-02-04 to 03-02-07] the connection point must only be drawn > when the connection is in crossing or identical branching [symbol > 03-02-09] wires/buses? Otherwise it should be an user configurable option. > > Maybe Kicad could use the same end-centered ring hint for all open > connections in addition to pins, also while drawing wires and buses. > > -Vesa > > > _______________________________________________ > Mailing list: https://launchpad.net/~kicad-developers > Post to : kicad-developers@lists.launchpad.net > Unsubscribe : https://launchpad.net/~kicad-developers > More help : https://help.launchpad.net/ListHelp _______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : kicad-developers@lists.launchpad.net Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp