On 09/20/2017 05:38 PM, jp charras wrote: > Le 20/09/2017 à 17:32, Maciej Sumiński a écrit : >> On 09/20/2017 05:29 PM, jp charras wrote: >> [snip] >>> After tests with 2 schematics I found a rounding issue in coordinates >>> (especially wires and pins): >>> Many coordinates are very near (1 mil, therefore one Eeschema unit) the 50 >>> mils grid but not exactly >>> on grid (for instance 499 instead of 500 mils) >>> The a few values I checked are smaller (one mil) than the grid coordinate, >>> so I am thinking this is >>> a rounding issue. >> >> Would you share an example schematic file, so we could investigate the >> problem? >> >> Regards, >> Orson > > Attached the 2 schematics I tested. > They can be found on Github.
Jean-Pierre, Could you help me find pins/wires that are not connected due to rounding errors? I did my best, but I cannot find anything neither by looking at the files saved in KiCad format nor in ERC reports. I noticed only missing junction marks on some of the T-shaped wire connections, but they are missing in the original Eagle files, so I assume it is fine. There is a minor bug that causes small squares on pins (as if they were not connected), but as soon you move a single component, they all disappear. This should be investigated, but it is not a rounding problem. Regards, Orson
signature.asc
Description: OpenPGP digital signature