From today’s l2switch call, I got action point to run system test on Li patch 
[1]:

https://jenkins.opendaylight.org/releng/view/l2switch/job/l2switch-csit-1node-switch-only-boron/291/robot/report/log.html

From the result above we can observe following issues:

- Flow push: There is no LLDP flows being pushed. Also flood flows seem to be 
in config space because operational shows flow ID.
- Address Tracker: All host IP addresses are seeing in all nodes, that is not 
right, only node connected to host should show the host.
- Host Tracker: After remove/add OpenFlow port (ovs-vsctl add-port), no host is 
learned anymore through that port.
- Loop Remover: Not working, using a loop topology, even when we observe some 
ports are in DISCARD mode, mininet sees DUP packets.

BR/Luis