Hi, Winston, Please refer to this solution, it is the same problem.
Thanks, Michael Gustavo Reyes wrote: > Sun Microsystems Inc. SunOS 5.11 snv_64a October 2007 > # /usr/sbin/HP-c300-bcm4311-enable > + rem_drv bcmndis > Driver (bcmndis) not installed. > + pcitool /pci at 0,0 -d bdf=0.1c.2,config -o 0x20 -s 4 -w 0xd000d000 > + pcitool /pci at 0,0 -d bdf=0.1c.2,config -o 4 -s 1 -w 0x46 > + add_drv -i "pci14e4,4311" bcmndis > # > >>>> Success !!! >>>> > # ifconfig bcmndis0 plumb > >>>> Success !!! >>>> > # ifconfig -a > lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 > index 1 > inet 127.0.0.1 netmask ff000000 > rtls0: flags=201004843<UP,BROADCAST,RUNNING,MULTICAST,DHCP,IPv4,CoS> mtu 1500 > index 2 > inet 10.254.71.190 netmask ffffff00 broadcast 10.254.71.255 > ether 0:16:d4:40:be:38 > bcmndis0: flags=201000802<BROADCAST,MULTICAST,IPv4,CoS> mtu 1500 index 3 > inet 0.0.0.0 netmask 0 > ether 0:14:a5:e1:7e:8 > lo0: flags=2002000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv6,VIRTUAL> mtu 8252 > index 1 > inet6 ::1/128 > >>>> Great !!! >>>> > > :DDDD > > Michael: > about these lines: pcitool /pci at 0,0 -d bdf=0.1c.2,config -o 0x20 -s 4 -w > 0xd000d000 && pcitool /pci at 0,0 -d bdf=0.1c.2,config -o 4 -s 1 -w 0x46... > Should I add them into a script, so they can be executed on every boot? > Many many thanks!!! > > Gustavo > > > This message posted from opensolaris.org > _______________________________________________ > laptop-discuss mailing list > laptop-discuss at opensolaris.org >