Dr. David Kirkby wrote:
> Hi Phi, 
> 6734667.tar.gz is [b]much[/b] better, but not totally flawless. 

Good to hear :)

> 
> First the good points:
> 
> 1) If booted with only a battery present, the battery charge monitor works 
> fine, detecting all changes correctly.
> 
> 2) If booted with both mains and a battery, the battery charge monitor works 
> fine, detecting all changes of both battery and mains.
> 
> 3) Insertion or removal of the battery is almost instantly reflected in the 
> monitor. 
> 
> 
> Now the bad points:
> 
> 1) If booted with only a mains connection, the battery charge monitor is 
> totally inoperative and is unable to display any changes made at all. 
> 
> The trace output shows the battery being connected
> 
> CPU FUNCTION                                 
>   1  -> acpi_drv_cbat_notify                  
> acpica`AcpiEvNotifyDispatch+0x7d
> 0x0
>   1    -> acpi_drv_cbat_notify                
> acpica`AcpiEvNotifyDispatch+0x7d
> 0x80
> 
> The dtrace code also shows the mains supply being removed
> 
>   1  -> acpi_drv_ac_notify                    
> acpica`AcpiEvNotifyDispatch+0x7d
> 0x80
> 
> but neither of these are reflected in the battery charge monitor when the 
> machine is booted with no battery present. 
> 
> 2) Whenever the mains is connected or disconnected, the changes take 20-30 
> seconds to show on the battery charge monitor. Why does this take a long 
> time, but battery changes reflected almost instantly?
> 

What does evprint show when you have these problems?

Phi

Reply via email to