i am currently using the PCI6014 i have set up the 8 input digital
channel, three differential channels and one NRSE channel. I would
like to know how to scan from the three differential channels as well
as set them up. Also since i am using a NRSE does it mean that i
connect AISENSE to AIGND? Channel 0 is used as the NRSE channel and
1&9,2&10,3&11 is used as the differential input.