Mike

What system is this - looks from your naiming that it is a T5220 - this 
does not have busses you can split and therefore cannot have a secondary 
I/O domain.

T

On 18/01/2010 15:22, Mike DeMarco wrote:
> Attempted to create a secondary IO domain from the configuration example in 
> the blog (which must not have been tested because it has several commands 
> flat out wrong).
> Anyway I was able to get the secondary configured and attempted to jumpstart 
> a OS onto the secondary by booting off the net. The boot vnet1 -s continues 
> to generate a message:
>
> WARNING: /virtual-devices at 100/channel-devices at 200/network at 0: Timeout 
> connecting to virtual switch... retrying
>
> And when I try to stop the domain with a ldm stop secondary It panics the 
> Hypervisor into a power down of the system.
>
> Here is the bindings list!
>
> ldm list-bindings
> NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  UPTIME
> primary          active     -n-cv-  SP      4     2G       0.3%  3m
>
> MAC
>      00:14:4f:22:30:20
>
> HOSTID
>      0x84223020
>
> CONTROL
>      failure-policy=ignore
>
> DEPENDENCY
>      master=
>
> VCPU
>      VID    PID    UTIL STRAND
>      0      0      0.3%   100%
>      1      1      0.2%   100%
>      2      2      0.3%   100%
>      3      3      0.7%   100%
>
> MAU
>      ID     CPUSET
>      0      (0, 1, 2, 3)
>
> MEMORY
>      RA               PA               SIZE
>      0x8000000        0x8000000        2G
>
> VARIABLES
>      auto-boot?=false
>      keyboard-layout=US-English
>      security-#badlogins=0
>
> IO
>      DEVICE           PSEUDONYM        OPTIONS
>      pci at 780          bus_a
>
> VCC
>      NAME             PORT-RANGE
>      primary-vcc      10500-10550
>
> VSW
>      NAME             MAC               NET-DEV   DEVICE     DEFAULT-VLAN-ID 
> PVID VID                  MTU   MODE
>      v522-vsw0        00:14:4f:fa:77:69 e1000g0   switch at 0   1             
>   1                         1500
>
> VDS
>      NAME             VOLUME         OPTIONS          MPGROUP        DEVICE
>      primary-vds0
>
> VCONS
>      NAME             SERVICE                     PORT
>      SP
>
> ------------------------------------------------------------------------------
> NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  UPTIME
> secondary        inactive   ------          4     1968M
>
> CONTROL
>      failure-policy=ignore
>
> DEPENDENCY
>      master=
>
> VSW
>      NAME             MAC               NET-DEV   DEVICE     DEFAULT-VLAN-ID 
> PVID VID                  MTU   MODE
>      v599s-vsw0       00:14:4f:fa:90:a1 e1000g3              1               
> 1                         1500
>
> VDS
>      NAME             VOLUME         OPTIONS          MPGROUP        DEVICE
>      secondary-vds0
>
> NETWORK
>      NAME             SERVICE                     DEVICE     MAC              
>  MODE   PVID VID                  MTU
>      vnet1            v599s-vsw0                             
> 00:14:4f:f9:96:be        1