On Sat, 11 Jan 2003 21:21:12 EST Tony wrote: > Eyal, > > Do you mean the 3c509 or the 3c905 module? You stated 905 below, and 509 in > one of your previous posts. I don't know about the 905 module, but the > 3c509.o most certainly does take the argument. > > That is what I am using right now and without it, the probe finds only one > card.
For the record, I have several LEAF boxes with multiple 3c509s in them. One has six 509s, another has five and several more have two each.) I do not use the "irq=" parameter with any of them and I have never had problems with them being recognized as long as they are properly configured via the DOS utility. I always disable the PnP setup and make sure they all use separate IRQs and non-overlapping I/O port addresses. I also insert them in order by MAC address into the ISA slots to protect my sanity when running cables. :-) --Brad ------------------------------------------------------- This SF.NET email is sponsored by: SourceForge Enterprise Edition + IBM + LinuxWorld = Something 2 See! http://www.vasoftware.com ------------------------------------------------------------------------ leaf-user mailing list: [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/leaf-user SR FAQ: http://leaf-project.org/pub/doc/docmanager/docid_1891.html