https://bugs.documentfoundation.org/show_bug.cgi?id=170796

            Bug ID: 170796
           Summary: BASIC runtime error. Property or method not found:
                    AccessibleContext.
           Product: LibreOffice
           Version: 26.2.0.3 release
          Hardware: x86-64 (AMD64)
                OS: Windows (All)
            Status: UNCONFIRMED
          Severity: normal
          Priority: medium
         Component: Calc
          Assignee: [email protected]
          Reporter: [email protected]

Description:
We open various Wizards and one of them failed with the error message:

BASIC runtime error.
Property or method not found: AccessibleContext.

We call this six times in various of our macros. My version updated to 26.2
overnight. Yesterday all the macros worked, now the ones that reference
AccessibleContext do not.



Steps to Reproduce:
1.In the attached spreadsheet go to Cell P9
2.Run the Sub EventInputWizard macro; or
3.Right click on Cell P9 and select the Event Input Wizard.

Actual Results:
The macro fails with this message:

BASIC runtime error. Property or method not found: AccessibleContext.

Expected Results:
The macros should run.


Reproducible: Always


User Profile Reset: No

Additional Info:
Here is one function that fails:

Function GetAccessibleSpreadsheet(ByVal oDoc) As Object

' Returns object (supports com.sun.star.AccessibleSpreadsheet interface)
corresponding to active sheet of Calc document.
' - oDoc  Spreadsheet document object.

  Dim oAccDoc

  GetAccessibleSpreadsheet=Nothing
 
oAccDoc=FindAccessibleRole(oDoc.CurrentController.ComponentWindow.AccessibleContext,
84)   ' 84 DOCUMENT_SPREADSHEET

  If Not (oAccDoc Is Nothing) Then 
        GetAccessibleSpreadsheet=FindAccessibleRole(oAccDoc.AccessibleContext,
58).AccessibleContext ' 58 TABLE 
  End If
End Function   ' GetAccessibleSpreadsheet

Version: 26.2.0.3 (X86_64)
Build ID: 620(Build:3)
CPU threads: 4; OS: Windows 11 X86_64 (build 26100); UI render: Skia/Raster;
VCL: win
Locale: en-CA (en_CA); UI: en-GB
Calc: CL threaded


Device name     AZC
Processor       Intel(R) Core(TM) i5-6500 CPU @ 3.20GHz (3.19 GHz)
Installed RAM   16.0 GB (15.9 GB usable)
Device ID       43C005FD-F30B-4F98-A0E5-17357AF05DBA
Product ID      00326-10000-00000-AA421
System type     64-bit operating system, x64-based processor
Pen and touch   No pen or touch input is available for this display


Edition Windows 11 Home
Version 24H2
Installed on    ‎2025-‎04-‎20
OS build        26100.7840
Experience      Windows Feature Experience Pack 1000.26100.291.0

-- 
You are receiving this mail because:
You are the assignee for the bug.