Use CP Q SIGNALS to see if they are "listening".

I believe I did nothing to /etc/inittab for SLES8 but instead updated the
/etc/zipl.conf to have a line like this:
parameters="dasd=0100,0201-020F root=/dev/dasdb1 vmpoff=LOGOFF
vmhalt=LOGOFF"

Marcy Cortes
Wells Fargo Services Company

-----Original Message-----
From: Monteleone [mailto:[EMAIL PROTECTED]
Sent: Monday, February 09, 2004 01:51
To: [EMAIL PROTECTED]
Subject: [LINUX-390] SLES8 trap signal shutdown


Hello,

I use the CP SIGNAL SHUTDOWN from a REXX CMS and it seems that my SLES8
guest don't really trap the signal. The logoff is done after the
timeout, but all files systems are not cleanly down.

Should I have to set a "ctraltdel" in my inittab like I done with SLES7
and bootshell program ?


Thanks for your help.


    Gerard MONTELEONE
  Ingenieur Systeme & Reseau
SI.TE.C Z.I du vazzio 20090 AJACCIO
* +33495236809 * +33687727032
              www.sitec.fr <http://www.sitec.fr/>

Reply via email to