FYI, an apar has been opened (below) and a workaround is presented for an
XRC suspend that occurs when formatting a VM minidisk.

Mary Anne

 APAR= OA26125  SER=                            MS MSGANTX5104E
 XRC ANTX5104E RC=0901 DURING FORMAT OF A VM MINIDISK

 STAT= OPEN         FESN0565517-     CTID= TU0260 ISEV= 2
 SB08/08/13  RC08/08/14  CL          PD           SEV= 2
                        PE=                       TYPE= F
 RCOMP= 5695DF117    SYSTEM DATA MOV RREL= R1K0
 FCOMP=                              PFREL= F     TREL= T
 ACTION=             SEC/INT= N                   DUP/
 USPTF=              PDPTF=                       DUPS 0


ERROR DESCRIPTION:
ANTX5104E RC=0901 occurs while formatting a VM minidisk that is
a primary in a XRC session, where XRC parameter PavVolumes is
greater than 1.

KEYWORDS:
ANTX5104E RC=0901 NRFITF NRF NO RECORD FOUND ITF INVALID TRACK
FORMAT MSGANTX5104E RC=901 RC0901 RC901
LOCAL FIX:
1. Change the PavVolumes parameter to 1 in the XRC parmlib
   member for future sessions, and use the XSET command to
   change the value of PavVolumes to 1 for the current sessions.

 - or -

2. Remove the pair from the XRC session before performing a
   format, then readd the pair after the format is complete.
    (recommended)

----------------------------------------------------------------------