>>> On 6/22/2009 at 12:31 PM, Dave Jones <d...@vsoft-software.com> wrote: 
> Hi, Mark.
> 
> Mark Post wrote:
>>>>> On 6/22/2009 at 11:41 AM, Dave Jones <d...@vsoft-software.com>
>>>>> wrote:
>> -snip-
>>> The real problem is that z/VM does not virtualize FCP-attached disk
>>> like it can do for ECKD and FBA devices....the WWPN and LUN values
>>> are "real" ones, and can not be shared across virtual machines.
>>
>> Of course they can be, otherwise clustering wouldn't be possible at
>> all.
>>
> How so, then? What I mean here is that FCP attached SCSI devices can not
> be "shared" across virtual machines the way CP handles sharing of 3390
> DASD, via the LINK statement.

That's what EDEVs are for.

> CP is not involved at all when Linux guests, as near as I can
> tell.....if two or more Linux guests share the same real SCSI device
> (same WWPN and LUN), then it's up to the guests themselves to manage access.

Correct, and that's a very well known and understood technology, whether using 
direct access by all systems involved or iSCSI.


Mark Post

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to lists...@vm.marist.edu with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390

Reply via email to