gmail thinks this is spam BTW.

On Sat, Oct 31, 2015 at 11:31 AM, Andrew F. Davis <a...@ti.com> wrote:
> Add the TI afe4404 heart monitor DT bindings documentation.
> Create health directory created under iio.
>
> Signed-off-by: Andrew F. Davis <a...@ti.com>
> ---
>  .../devicetree/bindings/iio/health/afe4404.txt     | 27 
> ++++++++++++++++++++++
>  1 file changed, 27 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/iio/health/afe4404.txt
>
> diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt 
> b/Documentation/devicetree/bindings/iio/health/afe4404.txt
> new file mode 100644
> index 0000000..d377033
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/iio/health/afe4404.txt
> @@ -0,0 +1,27 @@
> +* Texas Instruments AFE4404 Heart rate and Pulse Oximeter
> +
> +Required properties:
> + - compatible          : Should be "ti,afe4404".
> + - reg                 : I2C address of the device.
> + - led-supply          : Regulator supply to the device.

Is led correct name or copy-n-paste? The datasheet has tx_sup and
rx_sup for supplies.

> + - interrupt-parent    : Phandle to he parent interrupt controller.
> + - interrupts          : The interrupt line the device ADC_RDY pin is 
> connected to.
> +
> +Optional properties:
> + - reset-gpios         : GPIO used to reset the device.
> +
> +Example:
> +
> +&i2c2 {
> +       heart_mon@58 {
> +               compatible = "ti,afe4404";
> +               reg = <0x58>;
> +
> +               led-supply = <&vbat>;
> +
> +               interrupt-parent = <&gpio1>;
> +               interrupts = <28 IRQ_TYPE_EDGE_RISING>;
> +
> +               reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;
> +       };
> +};
> --
> 1.9.1
>
--
To unsubscribe from this list: send the line "unsubscribe linux-api" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html