The S3C Real Time Clock driver requires the clock and source clock to
be defined in the device node but that requirement is not documented.

Signed-off-by: Javier Martinez Canillas <jav...@osg.samsung.com>

---

 Documentation/devicetree/bindings/rtc/s3c-rtc.txt | 6 ++++++
 1 file changed, 6 insertions(+)

diff --git a/Documentation/devicetree/bindings/rtc/s3c-rtc.txt 
b/Documentation/devicetree/bindings/rtc/s3c-rtc.txt
index ac2fcd6ff4b8..1068ffce9f91 100644
--- a/Documentation/devicetree/bindings/rtc/s3c-rtc.txt
+++ b/Documentation/devicetree/bindings/rtc/s3c-rtc.txt
@@ -14,6 +14,10 @@ Required properties:
   interrupt number is the rtc alarm interrupt and second interrupt number
   is the rtc tick interrupt. The number of cells representing a interrupt
   depends on the parent interrupt controller.
+- clocks: Must contain a list of phandle and clock specifier for the rtc
+          and source clocks.
+- clock-names: Must contain "rtc" and "rtc_src" entries sorted in the
+               same order as the clocks property.
 
 Example:
 
@@ -21,4 +25,6 @@ Example:
                compatible = "samsung,s3c6410-rtc";
                reg = <0x10070000 0x100>;
                interrupts = <44 0 45 0>;
+               clocks = <&clock CLK_RTC>, <&s2mps11_osc S2MPS11_CLK_AP>;
+               clock-names = "rtc", "rtc_src";
        };
-- 
2.5.0

Reply via email to