On Mon, Mar 28, 2016 at 11:33:27AM +0200, Borislav Petkov wrote:
> On Mon, Mar 28, 2016 at 01:32:14PM +0800, Huang Rui wrote:
> >  
> >     return 0;
> > @@ -330,6 +446,9 @@ static int fam15h_power_init_data(struct pci_dev *f4,
> >  
> >     data->max_cu_acc_power = tmp;
> >  
> > +   /* set default interval as 10 ms */
> 
> Because...?
> 

I checked with HW designer, milliseconds is also a reasonable interval of acc 
power.
And I cannot set too long here, because several seconds will cause the
read function to hang for that period of time.

So I pick 10ms here, and actually, we can update the interval at
/etc/sensors3.conf

chip "fam15h_power-*"
        set power1_average_interval 0.01

Thanks,
Rui