On Thu, 2016-06-30 at 12:24 +0200, Thomas Gleixner wrote:
> On Thu, 30 Jun 2016, Mike Galbraith wrote:
> > On Thu, 2016-06-30 at 11:42 +0200, Thomas Gleixner wrote:
> > 
> > > So there was no watchdog firing for 525 seconds ????
> > 
> > Yup, seems so.
> 
> if that's fully reproducible can you please enable the timer and softirq
> tracepoints along with your trace printks and stop the trace when that
> watchdog triggers?

Lunch rendered me (yawn) comatose, so I'm a bit late, but sent.

        -Mike