Add Device Tree binding document for GE Healthcare USB Management
Controller (ACHC).

Signed-off-by: Martyn Welch <martyn.we...@collabora.co.uk>
---
 Documentation/devicetree/bindings/misc/ge-achc.txt | 26 ++++++++++++++++++++++
 1 file changed, 26 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/misc/ge-achc.txt

diff --git a/Documentation/devicetree/bindings/misc/ge-achc.txt 
b/Documentation/devicetree/bindings/misc/ge-achc.txt
new file mode 100644
index 0000000..77df94d
--- /dev/null
+++ b/Documentation/devicetree/bindings/misc/ge-achc.txt
@@ -0,0 +1,26 @@
+* GE Healthcare USB Management Controller
+
+A device which handles data aquisition from compatible USB based peripherals.
+SPI is used for device management.
+
+Note: This device does not expose the peripherals as USB devices.
+
+Required properties:
+
+- compatible : Should be "ge,achc"
+
+Required SPI properties:
+
+- reg : Should be address of the device chip select within
+  the controller.
+
+- spi-max-frequency : Maximum SPI clocking speed of device in Hz, should be
+  1MHz for the GE ACHC.
+
+Example:
+
+spidev0: spi@0 {
+       compatible = "ge,achc";
+       reg = <0>;
+       spi-max-frequency = <1000000>;
+};
-- 
1.8.3.1

Reply via email to