Add restart handler for SP805 watchdog so that the driver can be
used to reboot the system.

Signed-off-by: Jongsung Kim <neidhard....@lge.com>
Cc: Guenter Roeck <li...@roeck-us.net>
---
 drivers/watchdog/sp805_wdt.c | 13 +++++++++++++
 1 file changed, 13 insertions(+)

diff --git a/drivers/watchdog/sp805_wdt.c b/drivers/watchdog/sp805_wdt.c
index 03805bc..969369e 100644
--- a/drivers/watchdog/sp805_wdt.c
+++ b/drivers/watchdog/sp805_wdt.c
@@ -121,6 +121,18 @@ static unsigned int wdt_timeleft(struct watchdog_device 
*wdd)
        return div_u64(load, rate);
 }
 
+static int
+wdt_restart(struct watchdog_device *wdd, unsigned long mode, void *cmd)
+{
+       struct sp805_wdt *wdt = watchdog_get_drvdata(wdd);
+
+       writel_relaxed(0, wdt->base + WDTCONTROL);
+       writel_relaxed(0, wdt->base + WDTLOAD);
+       writel_relaxed(INT_ENABLE | RESET_ENABLE, wdt->base + WDTCONTROL);
+
+       return 0;
+}
+
 static int wdt_config(struct watchdog_device *wdd, bool ping)
 {
        struct sp805_wdt *wdt = watchdog_get_drvdata(wdd);
@@ -197,6 +209,7 @@ static const struct watchdog_ops wdt_ops = {
        .ping           = wdt_ping,
        .set_timeout    = wdt_setload,
        .get_timeleft   = wdt_timeleft,
+       .restart        = wdt_restart,
 };
 
 static int
-- 
2.7.4